Architectural and Transportation
Barriers Compliance Board
36 CFR Part
1191
[Docket No.
92-2]
RIN 3014
AA12
Published in the Federal Register January 13,
1998
These guidelines have
not been incorporated in the Department of Justice accessibility standards and
are, therefore, not enforceable.
Americans with Disabilities Act (ADA) Accessibility Guidelines
for Buildings and Facilities; State and Local Government Facilities
Preamble
Text of
Final Rule
AGENCY: Architectural and Transportation Barriers Compliance
Board.
ACTION: Final Rule.
SUMMARY: The Architectural and Transportation Barriers Compliance
Board (Access Board) is issuing final guidelines to provide additional guidance
to the Department of Justice and the Department of Transportation in
establishing accessibility standards for new construction and alterations of
State and local government facilities covered by title II of the Americans with
Disabilities Act (ADA) of 1990. The guidelines will ensure that newly
constructed and altered State and local government facilities are readily
accessible to and usable by individuals with disabilities in terms of
architecture, design, and communication. The standards established by the
Department of Justice and the Department of Transportation must be consistent
with the guidelines.
In addition to the provisions for State and local governments, the Access
Board has also made some editorial changes to the Americans with Disabilities
Act Accessibility Guidelines. These editorial changes are not substantive.
DATES: Effective date: April 13, 1998.
FOR FURTHER INFORMATION CONTACT: David Yanchulis, Office of Technical
and Information Services, Architectural and Transportation Barriers Compliance
Board, 1331 F Street NW., suite 1000, Washington, DC 20004-1111; telephone (202)
272-5434, ext. 27 or (800) 872- 2253 ext. 27 (voice), and (202) 272-5449 (TTY)
or (800) 993-2822 (TTY).
SUPPLEMENTARY INFORMATION:
Availability of Copies and Electronic Access
Single copies of this publication may be obtained at no cost by calling the
Access Board's automated publications order line (202) 272-5434 or (800)
872-2253, by pressing 1 on the telephone keypad, then 1 again and requesting the
State and Local Government Facilities Final Rule. Persons using a TTY should
call (202) 272-5449 or (800) 993-2822. Please record a name, address, telephone
number and request this publication. Persons who want a copy in an alternate
format should specify the type of format (audio cassette tape, Braille, large
print, or computer disk). This rule is available on electronic bulletin Board at
(202) 272-5448. A print copy of this rule can also be ordered by sending your
name and mailing address by email to pubs@access-board.gov and specifying
publication S-31.
The Americans with Disabilities Act of 1990 (ADA) (42 U.S.C. 12101 et seq.)
extends to individuals with disabilities comprehensive civil rights protections
similar to those provided to persons on the basis of race, sex, national origin,
and religion under the Civil Rights Act of 1964. Title II of the ADA, which
became effective on January 26, 1992, prohibits discrimination on the basis of
disability in services, programs and activities provided by State and local
government entities, and the National Railroad Passenger Corporation (Amtrak).
Section 202 of the ADA extends the nondiscrimination policy of section 504 of
the Rehabilitation Act of 1973, as amended, (29 U.S.C. 794) which prohibits
discrimination on the basis of disability in federally assisted programs and
activities to all State and local governmental entities whether or not such
entities receive Federal funds. Most programs and activities of State and local
governments are recipients of financial assistance from one or more Federal
agencies and are already covered by section 504 of the Rehabilitation Act of
1973.
Title III of the ADA, which also became effective on January 26, 1992,
prohibits discrimination on the basis of disability by private entities who own,
lease, lease to, or operate a place of public accommodation. Title III
establishes accessibility requirements for new construction and alterations in
places of public accommodation and commercial facilities.
Section 504 of the ADA requires that the Access Board issue minimum
guidelines to assist the Department of Justice and the Department of
Transportation in establishing accessibility standards under titles II and III.
Under sections 204(a) and 306(b) of the ADA, the Department of Justice is
responsible for issuing final regulations, consistent with the guidelines issued
by the Access Board, to implement titles II and III (except for transportation
vehicles and facilities). Sections 229 and 306(a) of the ADA provide that the
Department of Transportation is responsible for issuing regulations to implement
the transportation provisions of titles II and III of the ADA. Those regulations
must also be consistent with the Access Board's guidelines.
Rulemaking History
On July 26, 1991, the Access Board published the Americans with Disabilities
Act Accessibility Guidelines (ADAAG) to assist the Department of Justice in
establishing accessibility standards for new construction and alterations in
places of public accommodation and commercial facilities. See 56 FR 35408, as
corrected at 56 FR 38174 (August 12, 1991) and 57 FR 1393 (January 14, 1992), 36
CFR part 1191. ADAAG contains scoping provisions and technical specifications
generally applicable to buildings and facilities (sections 1 through 4) and
additional requirements specifically applicable to certain types of buildings
and facilities covered by title III of the ADA: restaurants and cafeterias
(section 5); medical care facilities (section 6); mercantile and business
facilities (section 7); libraries (section 8); and transient lodging (section
9).1
On July 26, 1991, the Department of Justice published its final regulations
implementing title III of the ADA which incorporated ADAAG as the accessibility
standards for newly constructed and altered places of public accommodation and
commercial facilities covered by title III. See 56 FR 35544, 28 CFR part 36. On
that same date, the Department of Justice published its final regulations
implementing title II of the ADA. See 56 FR 35694, 28 CFR part 35. The
Department of Justice's title II regulations give State and local governments
the option of choosing between designing, constructing or altering their
facilities in conformance with the Uniform Federal Accessibility Standards
(UFAS)2 (Appendix A to 41 CFR part 101-19, subpart 19.6) or with
ADAAG (Appendix A to 28 CFR part 36), except that if ADAAG is chosen, the
elevator exemption contained in title III of the ADA does not apply.3
See 28 CFR 35.151.
When the Department of Justice published its title II regulations, it noted
that the Access Board would be supplementing ADAAG in the future to include
additional guidelines for State and local government facilities. The Department
of Justice further stated that it anticipated that it would amend its title II
regulations to adopt ADAAG as the accessibility standards for State and local
government facilities after the Access Board supplemented ADAAG. 56 FR 35694,
35711 (July 26, 1991). Adopting essentially the same accessibility standards for
titles II and III of the ADA will help ensure consistency and uniformity of
design in the public and private sectors throughout the country.
Proposed Guidelines
On December 21, 1992, the Access Board published a notice of proposed
rulemaking (NPRM) in the Federal Register which proposed to add four
special application sections to ADAAG specifically applicable to certain types
of buildings and facilities covered by title II of the ADA. Those special
application sections include:
11. Judicial, Legislative, and Regulatory Facilities.
12. Detention and Correctional Facilities.
13. Accessible Residential Housing.
14. Public Rights-of-Way.
The NPRM also proposed requirements and asked questions regarding the
addition of miscellaneous provisions specifically applicable to State and local
government facilities, including swimming pools, text telephones (TTYs),
automatic doors, airport security systems, entrances, elevator exemptions,
building signage, assistive listening systems, and sales and service counters.
57 FR 60612 (December 21, 1992).
Following the publication of the NPRM, the Access Board held five public
hearings in various locations between February 22, 1993 and March 15, 1993. A
total of 148 people presented testimony on the proposed guidelines at the
hearings. In addition, 447 written comments were submitted to the Access Board
by the end of the comment period on March 22, 1993. Another 127 comments were
received after March 22, 1993. Although those comments were not timely, the
Access Board considered them to the extent practicable. In all, the Access Board
received nearly 7000 pages of comments and testimony on the proposed
guidelines.
Interim Rule
On June 20, 1994, the Access Board published an interim rule (hereinafter
referred to as the interim rule) in the Federal Register which added
sections 11 through 14 and miscellaneous provisions to ADAAG. 59 FR 31676 (June
20, 1994) as corrected at 59 FR 32751 (June 24, 1994). Many of the comments
received by the Access Board in response to the December 21, 1992 NPRM and the
public hearings, as well as modifications made to the NPRM based on the
comments, were discussed in the June 20, 1994 interim rule.
On that same date, the Department of Justice and the Department of
Transportation published notices of proposed rulemakings to adopt as standards
sections 11 through 14 and the miscellaneous provisions of the Access Board's
interim rule. See 59 FR 31808; June 20, 1994, Department of Justice; 59 FR
31818; June 20, 1994, Department of Transportation. Both the Access Board's
interim rule and the notices of proposed rulemaking published by the departments
of Justice and Transportation sought comment on sections 11 through 14 and the
miscellaneous provisions, as published in the Federal Register on June 20,
1994.
Final Rule
As discussed above, the Access Board's guidelines provide guidance to the
departments of Justice and Transportation in establishing accessibility
standards for new construction and alterations of State and local government
facilities covered by title II of the ADA. The standards ultimately established
by those departments must be consistent with and may incorporate the guidelines.
It is important to note that until such time as the Department of Justice or
the Department of Transportation adopt these guidelines as standards, the
guidelines are advisory only and are not to be construed as requirements.
In finalizing the guidelines, the Access Board has considered all comments
previously received in response to the Access Board's NPRM for State and local
government facilities published on December 21, 1992, as well as comments
received in response to the Access Board's interim rule and the departments of
Justice and Transportation's notices of proposed rulemaking.
The Access Board and the departments received comments and testimony from a
broad range of interested individuals and groups, including individuals who
identified themselves as having a disability; organizations representing persons
with disabilities; State or local code administrators; State, local and Federal
government agencies; manufacturers; design professionals; and national
professional and trade associations. In all, the Access Board and the
departments of Justice and Transportation received 246 comments totaling over
1200 pages on the interim rule.
The comments and testimony were sorted by section and analyzed. A large
number of commenters expressed support for the guidelines. Some comments
requested changes and others requested clarifications. Due to the large number
of comments received, it is not possible for the Access Board to respond to each
comment in this preamble. Many of the comments received in response to the
initial NPRM were discussed in the interim rule. A copy of that interim rule is
available upon request. (See: For Information Contact, above.) The Access Board
has made every effort to respond to significant comments in the general issues
and section-by-section analysis. As discussed under general issues and in ADAAG
13 (Accessible Residential Housing) and 14 (Public Rights-of-Way), the Access
Board has reserved action in some areas pending further analysis.
Editorial Amendments
Under section 502 of the Rehabilitation Act of 1973 (29 U.S.C. 792), the
Access Board is responsible for establishing guidelines for accessibility
standards issued by other Federal agencies pursuant to the Architectural
Barriers Act of 1968 (42 U.S.C. 4151 et seq.). To further the goal of uniform
standards, the Access Board intends to use ADAAG as the basis for accessibility
guidelines for federally financed facilities covered by the Architectural
Barriers Act of 1968 since the Federal government owns or operates many of the
same types of facilities as State and local governments which are addressed in
this final rule. In the near future, the Access Board anticipates revising its
current guidelines for federally financed facilities to be more consistent with
ADAAG. As a result, the Access Board has made a number of editorial revisions to
accommodate the use of ADAAG as the basis for revising the guidelines covering
Federal facilities.
The editorial changes made to facilitate the application of the provisions of
ADAAG to Federal facilities in future rulemaking and any other clarifying
editorial changes are addressed in the section-by-section analysis that follows.
None of the editorial changes made in this final rule are substantive and
therefore do not require the issuance of an additional proposed rule.
General Issues
Unisex Toilet and Bathing Facilities
The Access Board received a number of comments concerning the need for unisex
toilet and bathing facilities to accommodate people with personal attendants of
the opposite sex. In the interim rule, the Access Board noted that it would
examine appropriate means of addressing this issue. In May 1994, the Access
Board held an informational workshop to discuss the issue of scoping
requirements for unisex toilet and bathing facilities. Subsequently, at the
Access Board's request, the Board for the Coordination of Model Codes (BCMC)
developed scoping provisions for unisex toilet and bathing facilities. BCMC
recommended single-user toilet and bathing facilities in assembly and mercantile
occupancies where an aggregate of six or more fixtures (e.g., toilets for either
men or women) are provided. Assembly occupancies include, but are not limited
to, theaters, museums, nightclubs, stadiums, amusement parks, restaurants,
health clubs and transportation facilities. Mercantile occupancies include
public accommodations for display and sales purposes, such as stores and
shopping malls. The BCMC report has been incorporated, with minor modification,
into the Uniform Building Code (UBC), the Standard Building Code (SBC) and the
National Building Code (BOCA). The Access Board will continue to participate in
the advancement of the recommendations of the BCMC report. The Access Board
anticipates that the provisions concerning unisex toilet and bathing facilities
will be included in the International Building Code as it is developed for
publication in the year 2000.
Swimming Pools
The interim rule contained a requirement that at least one means of access be
provided into swimming pools covered by title II if the pool was intended for
recreational purposes and not intended solely for diving or wading. Technical
specifications for pool access were not provided. This requirement has been
removed in the final rule.
Comment. While many commenters supported a requirement for pool
access, concern was also expressed over the absence of any technical guidance on
meeting the requirement. Commenters noted that the ADAAG specifications for
ramps in 4.8.5 require handrails which, if applied to swimming pool access, may
pose a hazard below the water level to swimmers and that devices, such as
sling-type lifts, were not independently operable. Commenters varied greatly on
what means of access into swimming pools should be required. The suitability of
the available design solutions depended on the needs and preferences of
individual users. It was recommended that any requirement for pool access
include technical specifications to prevent confusion and for safety reasons.
Commenters also considered pool access equally important for facilities covered
by title III of the ADA.
Response. The Access Board established a Recreation Access Advisory
Committee to provide recommendations for the development of accessibility
guidelines for swimming pools, other recreational facilities, and outdoor
developed areas. This advisory committee identified important considerations in
providing access into swimming pools that merit further study. As a result, the
Access Board sponsored research on these issues to obtain information necessary
for the development of possible future technical specifications. The requirement
for access into pools has been removed. The Access Board will consider the
results of the study, as well as the advisory committee's recommendations, when
it conducts a separate rulemaking in the future to address recreational
facilities. These future guidelines will apply to entities covered by both
titles II and III of the ADA.
Other Issues
Several comments addressed other issues raised in the NPRM and discussed in
the interim rule, such as assembly areas, and voting booths. Many of these
comments supported rulemaking in these areas. While the Access Board may address
these issues in future rulemaking, it is not prepared to do so as part of this
final rule.
Section-by-Section Analysis
This section of the preamble contains a summary of the significant comments
received on the interim rule, and the departments of Justice and
Transportation's NPRMs, the Access Board's response to those comments, and any
changes made to the guidelines.
1. Purpose
In section 1 (Purpose) and throughout ADAAG, the reference to sections 4.1
through 4.35 has been deleted and replaced with a general reference to section
4. Additionally, the reference to "guidelines" has been replaced with "scoping
and technical requirements". These are editorial amendments and are not
substantive changes. No other changes have been made to this section.
3. Miscellaneous Instructions and Definitions
3.5 Definitions
Alteration
The definition for "alteration" in the interim rule included references to
pedestrian facilities in the public right-of-way. This language has been
removed. For further discussion, see ADAAG 14 below.
The interim rule also added a specific reference to "resurfacing" in the
definition for "alterations". The addition of the term "resurfacing" was not
intended as a new interpretation of what constitutes an alteration, but rather
to reinforce the original intent that the resurfacing of streets, sidewalks,
parking lots, and other outdoor surfaces is considered an alteration. The term
"resurfacing" has been retained in the final rule, however, the application of
the term has been clarified.
Comment. A few commenters were concerned that the inclusion of the
term "resurfacing" would broaden the scope of compliance to minor street
repair.
Response. The term "resurfacing" does not include minor repair work to
parking lots and paved surfaces, such as repainting existing striping or repair
of potholes. By definition, "alteration" excludes normal maintenance that does
not affect the usability of a facility. Repairing potholes would be an example
of normal maintenance. Other relatively minor tasks, such as restriping of a
parking lot, may constitute alterations because they affect the usability of the
facility by creating an opportunity to increase accessibility. However, the
obligation triggered by such an alteration is limited by the scope of the
planned alteration. In the case of restriping, the obligation would be to make
the altered element itself (e.g., the striping) conform to the provisions of
these guidelines.
Assembly Area
ADAAG provides requirements for wheelchair seating and assistive listening
systems in certain "assembly areas." See ADAAG 4.1.3(19). These requirements are
intended to apply to judicial, legislative, and regulatory facilities which are
addressed in section 11. "Assembly Area" is defined, in part, as "a room or
space accommodating a group of individuals for recreation, educational,
political, social or amusement purposes." For clarity, a reference to "civic"
purposes has been added.
Continuous Passage
The definition for "continuous passage" in the interim rule referenced ADAAG
14 (Public Rights-of-Way). This definition has been removed. For further
discussion, see ADAAG 14 below.
Curb Ramp
The definition for "curb ramp" in the interim rule included a reference to
ADAAG 14 (Public Rights-of-Way). This language has been removed. For further
discussion, see ADAAG 14 below.
Dwelling Unit
The definition for "dwelling unit" in the interim rule included a reference
to ADAAG 13 (Accessible Residential Housing). This language has been removed.
For further discussion, see ADAAG 13 below.
Private Facility and Public Facility
The final rule includes definitions for "private facility" and for "public
facility." "Private facility" is defined as a public accommodation or a
commercial facility subject to title III of the ADA and the Department of
Justice implementing regulation (28 CFR part 36) or a transportation facility
subject to title III of the ADA and the Department of Transportation's ADA
regulation covering facilities constructed or altered by private entities (49
CFR 37.45). "Public facility" is defined as those facilities or portions thereof
that are constructed by, on behalf of, or for the use of a public entity subject
to title II of the ADA and the Department of Justice implementing regulation (28
CFR part 35) or a transportation facility subject to title II of the ADA and the
Department of Transportation's regulations implementing the ADA as it applies to
facilities constructed or altered by public entities (49 CFR 37.41 and 49 CFR
37.43). These terms are included in the final rule to distinguish certain
requirements in the rule that apply only to facilities subject to title II or to
facilities subject to title III, but not both. The terms replace references to
"places of public accommodation and commercial facilities" and to references in
the interim final rule to "facilities subject to title II of the ADA."
Public Rights-of-Way
The definition for "public rights-of-way" in the interim rule referenced
ADAAG 14 (Public Rights-of-Way). This definition has been removed. For further
discussion, see ADAAG 14 below.
Public Sidewalk
The definition for "public sidewalk" in the interim rule referenced ADAAG 14
(Public Rights-of-Way). This definition has been removed. For further
discussion, see ADAAG 14 below.
Public Sidewalk Curb Ramp
The definition for "public sidewalk curb ramp" in the interim rule referenced
ADAAG 14 (Public Rights-of-Way). This definition has been removed. For further
discussion, see ADAAG 14 below.
Site Infeasibility
The definition for "site infeasibility" in the interim rule referenced ADAAG
14 (Public Rights-of-Way). This definition has been removed. For further
discussion, see ADAAG 14 below.
TTY, TDD, and Text Telephone
The interim rule included editorial revisions concerning the use of the terms
"text telephone" and "TTY". Both terms are synonymous and refer to devices that
make telephones accessible to people who are deaf or hard of hearing or who have
speech impairments via typed messages through the standard telephone network.
The interim rule replaced the term "text telephone" with "TTY" in this section
and throughout ADAAG. The final rule amends ADAAG 3.5 (Definitions), 4.1.3(17),
4.30.7, and 4.31.9 to include a reference to both "text telephone" and "TTY" for
clarity. In addition, "TDD," another synonymous term which is used on the
international symbol for these devices and in other regulations, has been added
to ADAAG 3.5 (Definitions).
Comment. Organizations representing people who are deaf or hard of
hearing preferred the original use of the term text telephone as it is more
descriptive than abbreviated terms such as TTY. Other commenters recommended
that both text telephone and TTY be used in ADAAG as the abbreviation TTY is
more commonly used.
Response. The definition of TTY in the interim rule has been amended
to reference the definition of text telephone. A reference to TTYs has been
added to the definition of text telephone. ADAAG has been modified to include
both text telephone and TTY when referencing devices that make telephones
accessible to people who are deaf or hard of hearing or who have speech
impairments.
Technically Infeasible
This term and a reference to its definition in alterations (4.1.6(1)(j)) was
added in the interim rule for clarification. No substantive comments were
received and no changes have been made to this definition.
Transient Lodging
The interim rule modified the definition of "transient lodging" to clarify
that a transient lodging facility is not considered a residential facility. An
appendix note was added referencing the Department of Justice's policy and rules
regarding transient lodging. No substantive comments were received regarding
this definition or the appendix note and no changes have been made to this
provision or the appendix note.
4. Accessible Elements and Spaces: Scope and Technical
Requirements
4.1 Minimum Requirement
4.1.1 Application
4.1.1(1) General
4.1.1(2) Application Based on Building Use
ADAAG 4.1.1(1) (General) and 4.1.1(2) (Application Based on Building Use)
were editorially revised in the interim rule for clarity. Few comments were
received regarding these sections and no substantive changes have been made in
the final rule.
4.1.1(5) General Exceptions
As revised in the interim rule, ADAAG 4.1.1(5)(b) exempts from the
requirements for accessibility, prison guard towers, fire towers, fixed life
guard towers, and other areas raised for purposes of security or life or fire
safety; non-occupiable spaces accessed only by tunnels and frequented only by
personnel for maintenance or occasional monitoring of equipment; and single
occupant structures accessed only by passageways above or below grade. A
reference to "lookout galleries" has been added to the final rule for
clarification. No substantive changes have been made to this provision in the
final rule.
Comment. One disability group opposed the exceptions for fire towers
and prison guard towers. Both the Eastern Paralyzed Veterans Association (EPVA)
and the Paralyzed Veterans of America opposed exceptions for toll booths. These
commenters pointed to the employment opportunities available to persons with
disabilities at such facilities. In addition, EPVA provided information
regarding a newly built facility where elevator access has been provided to toll
booths accessed from tunnels below. One commenter expressed support for the
exception for non- occupiable spaces.
Response. Originally, ADAAG 4.1.1(5)(b) provided that accessibility
was not required to "(i) observation galleries which were used primarily for
security purposes; or (ii) non-occupiable spaces which were accessed only by
ladders, catwalks, crawl spaces, very narrow passageways, or freight
(non-passenger) elevators, and frequented only by service personnel for repair
purposes" (e.g., elevator pits, elevator penthouses, piping or equipment
catwalks). The interim rule amended the language of 4.1.1(5)(b)(i) by providing
that accessibility was not required to "raised areas used primarily for purposes
of security or life or fire safety" (e.g., observation galleries, prison guard
towers, fire towers or fixed life guard stands). Section 4.1.1(5)(b)(ii), as
amended in this final rule, includes a reference to areas "frequented only by
service personnel for maintenance, repairs, or occasional monitoring of
equipment" in lieu of areas "frequented only by service personnel for repair
purposes". The interim rule provided several examples of such areas, including
water or sewage treatment pump rooms and stations, electric substations and
transformer vaults, and highway and tunnel utility facilities. The final
amendment to this provision includes the addition of a third paragraph
referencing single occupant structures accessed only by passageways below grade
or elevated above grade, including, but not limited to, toll booths that are
required to be accessed from underground tunnels. This provision was not
intended to exempt structures accessed by passageways merely elevated by a curb
and has been clarified in the final rule as applying to single occupant
structures that are accessed by passageways elevated above standard curb
height.
The additions made to 4.1.1(5)(b) in the interim rule were not intended to
broaden the basis of exempt areas, but to address structures specific to the
public sector that are similar to those areas which were exempt under the
earlier version of this provision because of design constraints. The examples
specifically referenced in the interim rule as exempt areas, such as prison
guard, fire, and fixed life guard towers are subject to design constraints which
are similar to, if not greater than, those relevant to observation galleries
raised for security purposes. Since these facilities are typically for limited
use and not open to the public, the Access Board sought to provide accessibility
requirements for State and local government facilities consistent with the level
of access required for the private sector.
With respect to toll booths, elevator or lift access may provide access to
booths accessed from tunnels below or passageways above. However, providing
elevators or lifts in full compliance with ADAAG will significantly impact the
design and cost of such structures. The exception applies only to toll booths
accessed from below or above grade, not to those that can be accessed at
grade.
Comment. A correctional entity recommended that prison boot camps,
national guard facilities, and firing ranges be exempt since such facilities are
typically not intended to serve persons with disabilities.
Response. As discussed in the interim rule, the Access Board has not
provided any exceptions based on the presumed physical abilities of the
occupants of the facilities. Instead, exceptions in 4.1.1(5)(b) are based
primarily on the structural and cost impacts of access to certain limited use
structures.
Comment. One commenter recommended an exemption for elevated control
rooms such as those found in correctional facilities.
Response. Such facilities, depending on their design and use, may be
exempt under the exception for "raised areas used primarily for purposes of
security."
4.1.3(5) Elevators
The interim rule added several exceptions to the requirement for elevator
access for State and local government facilities.
Exception 1(a) of ADAAG 4.1.3(5) contains an exception based on the number of
stories or square footage per floor specific to private facilities, which are
defined in 3.5 as those facilities subject to title III of the ADA.
Exception 1(b) of ADAAG 4.1.3(5) provides that elevators are not required in
drawbridge towers and boat traffic towers, lock and dam control stations, train
dispatching towers and similar structures subject to title II of the ADA as a
public facility that are less than three stories and not open to the public,
where the story above or below the accessible ground floor houses no more than
five persons and is less than 500 square feet. This provision has been
editorially revised for clarity.
Comment. One commenter opposed this exception because it may deny
persons with disabilities certain job opportunities. Another commenter
recommended that the language of the exception, including the reference to
"similar structures," be more specific.
Response. Exception 1(b) is based on the design and cost impact of
providing elevator access in small limited use structures and applies only to
those facilities that are less than three stories, are not open to the public,
and where the story above or below the accessible ground floor has a maximum
occupancy of five and is less than 500 square feet. Each of these conditions
must be met for the exemption to apply. Specific facilities such as drawbridge
and boat traffic towers, lock and dam control stations, and train dispatching
towers are referenced to illustrate the type of structures the exception may
cover.
Exception 4 (Platform Lifts)
The interim rule also recognized additional situations in which a platform
lift can be used to provide vertical access. Exception 4(e) to ADAAG 4.1.3
permits lift access to judges' benches, clerks' stations, raised speakers'
platforms, jury boxes and witness stands. It is possible that some designs may
include areas that are lower than the floor of a courtroom, such as the well of
the court, instead of raised spaces such as jury boxes. For clarity and
consistency, a reference has been added to "depressed areas" in addition to the
raised spaces originally listed. Exception 4(f) which applied specifically to
dwelling units has been deleted in the final rule. For further discussion
regarding the application of accessibility requirements for dwelling units, see
ADAAG 13 (Accessible Residential Housing) below.
Exception 5 (Air Traffic Control Towers)
Exception 5 exempts air traffic control towers from the requirement that an
elevator serve each level of a facility. Under this exception, elevator access
is not required to the cab or to the floor immediately below the cab since an
elevator serving such levels would obstruct the 360- degree clear view necessary
in an air traffic control tower. No changes have been made to this provision in
the final rule.
Comment. A few comments opposed the exception for air traffic control
towers since possible design alternatives currently under review, (e.g., the use
of glass observation elevators), may provide feasible solutions to the problem
of providing an unobstructed 360-degree clear view.
Response. As discussed in the interim rule, the exception for air
traffic control towers is based on the impact of providing vertical access to
the cab level. While solutions for this access may exist, their impact on design
is significant according to information from the Federal Aviation
Administration. It is for these reasons that an exception for vertical access to
the cab and the level immediately below the cab has been provided.
4.1.3(8) Entrances
ADAAG 4.1.3(8)(a) requires that, at a minimum, 50 percent of all public
entrances be accessible. It also requires accessible entrances to be provided in
a number at least equivalent to the number of exits required by the applicable
building or fire code. However, this is required only to the extent that the
number of entrances planned for a facility is equal to or greater than the
number of exits required; if the number of exits exceeds the number of planned
entrances, all planned entrances are required to be accessible. Additional
entrances are not required. Paragraph (a) also states that, "where feasible,
accessible entrances shall be those used by the majority of the people visiting
or working in the building." The interim rule added an additional requirement
that facilities subject to title II of the ADA must include all "principal
public entrances" when meeting this requirement. These entrances were defined as
those entrances designed and constructed to accommodate a substantial flow of
pedestrian traffic to a major function in a facility subject to title II.
Appendix material provided examples to clarify the application of this
requirement. This requirement, definition, and appendix note for principal
public entrances has been removed in the final rule. Since ADAAG requires access
to entrances used by the majority of visitors or employees where feasible, the
Board considered the requirement for principal public entrances in the interim
final rule as a possible source of confusion. Further, the Board is concerned
that designers might have difficulty determining which entrances constituted a
"principal public entrance." In addition, editorial revisions have been made to
this section for clarity and consistency.
ADAAG 12 (Detention and Correctional Facilities) requires that public
entrances, including entrances that are secured, shall be accessible as required
by 4.1.3(8). This requirement does not increase the number of entrances required
to be accessible by 4.1.3(8) and provides an exception from certain ADAAG
specifications for doors and doorways. This exception applies to doors or
doorways operated only by security personnel or where security requirements
prohibit full compliance with the guidelines. See ADAAG 12.2.1. A cross
reference to this section has been added to 4.1.3(8)(a) in the final rule.
ADAAG 4.1.3(8)(b) requires that, where provided, one direct entrance to an
enclosed parking garage and one entrance to a pedestrian tunnel or elevated
walkway must be accessible in addition to those entrances required to be
accessible by 4.1.3(8)(a). ADAAG 11 contains additional requirements for access
to restricted and secured entrances in judicial, legislative, and regulatory
facilities. A cross reference to these requirements has been added to
4.1.3(8)(b) in the final rule.
4.1.3(17)(c) Text Telephones (TTYs)
ADAAG 4.1.3(17)(c)(i) provides that if an interior public pay telephone is
provided in a public use area of a building that is part of a public facility,
then at least one interior public text telephone (TTY) shall be provided in the
building in a public use area. This requirement, which was located at
4.1.3(17)(c)(iv) in the interim rule, has been revised to cover "buildings"
instead of "facilities" for clarity. The existing requirement for a public text
telephone where four or more public pay telephones are provided on a site and at
least one is in an interior location has been clarified as applying to private
facilities subject to title III of the ADA.
ADAAG 4.1.3(17)(c)(ii) requires that in public facilities that are stadiums,
arenas and convention centers, at least one public text telephone (TTY) shall be
provided on each floor level having a public pay telephone. ADAAG
4.1.3(17)(c)(iv) requires that if an interior public pay telephone is provided
in a secured area of a detention or correctional facility, then at least one
public text telephone (TTY) shall be provided in at least one secured area.
ADAAG 4.1.3(17)(d) provides that, where a bank of telephones in the interior of
a building consists of three or more public pay telephones, at least one public
pay telephone in each such bank shall be equipped with a shelf and outlet in
compliance with ADAAG 4.31.9(2). This provision contains an exception for the
secured areas of detention or correctional facilities where outlets are
prohibited for purposes of security or safety. No substantive changes have been
made to these sections.
Comment. Several commenters supported this provision. Other commenters
supported an increase in the number of text telephones (TTYs) required and
offered various recommendations. The American Public Communications Council, a
trade association comprised of suppliers of public pay telephones and other
services, was concerned that the requirement could have the unintended result of
decreasing the number of public pay telephones available to all members of the
public. They stated that the business of providing public pay telephones
operates on a very thin margin and the increased investment cost of an
additional $1000 or more may mean that neither independent public pay telephone
providers nor local exchange carriers will be able or willing to provide a
public pay telephone in a low-traffic facility. The commenter submitted
documentation detailing a few instances where telephone companies have removed
public pay telephones because the pay telephones were deemed not to be
profitable.
Response. It is the covered entity that has the responsibility to
ensure that the public pay telephone service is accessible to persons with
disabilities and to select from the various options available on how to provide
that service. In developing the interim rule, the Access Board considered the
options currently available. The cost for text telephones (TTYs) generally
ranges from $230 to $300 for portable devices and $700 to $1200 for those
permanently installed. In addition, text telephones (TTYs) may be leased for
approximately $30 a month under programs that include long-term maintenance and
technology upgrade services. ADAAG 4.31.9(3) includes a provision for equivalent
facilitation which permits the use of portable devices, in lieu of permanently
installed public text telephones (TTYs), if the portable device is equally
available during the same hours as the public pay telephone. This provision
ensures equal access, and allows the entity greater flexibility in selecting a
secure and cost effective method of providing access. For example, an
administrative office in a town hall may provide a portable text telephone (TTY)
for use in the office or at public telephones as long as the office is open to
the public the same hours that the public telephone is available for use by the
public. Directional signage must be provided at the public pay telephones
indicating the location of the text telephone (TTY).
Comment. One commenter requested clarification of the term "public use
area".
Response. ADAAG 3.5 (Definitions) defines "public use" as the interior
or exterior rooms or spaces that are made available to the general public. Some
entities covered under title II of the ADA may not have a public use area.
4.1.6 Accessible Buildings: Alterations
4.1.6(1)(k) Elevator Exception
This provision states that the exception to the requirement for an elevator
in ADAAG 4.1.3(5) for newly constructed facilities also applies to altered
facilities. This exception was editorially revised in the interim rule
consistent with the revision of ADAAG 4.1.3(5). No changes have been made to
this provision in the final rule.
4.1.7 Accessible Buildings: Historic Preservation
4.1.7(1)(a) Exception
This section addresses the requirements for access in alterations to
qualified historic facilities. The interim rule contained an exception
referencing provisions for program access in the Department of Justice's title
II and III regulations where compliance with ADAAG would threaten or destroy the
historic significance of a facility. See 28 CFR 35.151(d)(2) and 28 CFR
36.405(b). This provision has been relocated to the appendix as it did not
function as an "exception" to ADAAG but as an advisory note.
4.33 Assembly Areas
4.33.7 Types of Listening Systems
Information was submitted which addressed the incompatibility of some
receivers with hearing aids. People who wear hearing aids often need them while
using an assistive listening system. A requirement for hearing-aid compatibility
was not included in the proposed or interim final rules. The Access Board
intends to consider this issue in future rulemaking which would address assembly
areas in general. However, the Department of Justice's regulations implementing
titles II and III of the ADA require public entities and public accommodations
to provide appropriate auxiliary aids and services where necessary to ensure
effective communication. Where assistive listening systems are used to provide
effective communication, the Department of Justice considers it essential that a
portion of receivers be compatible with hearing aids. This information has been
added to an appendix note to section 4.33.7.
Special Occupancy Sections: 5. Restaurants and Cafeterias
through 10. Transportation Facilities
General provisions in each of these sections have been editorially revised to
refer to "section 4" of ADAAG instead of section "4.1. to 4.35" to facilitate
future revision of the guidelines.
7. Business, Mercantile and Civic
This section addresses business, mercantile, and civic occupancies. In the
final rule, a reference to "civic" has been added to clarify the applicability
of this section to state and local government facilities.
7.2 Sales and Service Counters, Teller Windows, Information
Counters
ADAAG 7.2(1) and (2) require access at sales and service counters, teller
windows, and information counters in State and local government facilities where
goods and services are available to the public. Both provisions are existing
requirements which have been editorially revised to include their application to
State and local government facilities as well. Section 7.2(3) of the interim
rule contained the requirements for State and local governments. These
requirements are no longer necessary with the editorial revisions to 7.2(1) and
(2). ADAAG 7.2(3) requires access to facilitate voice communication at counters
and teller windows with solid partitions or security glazing provided in public
facilities. This provision also requires that, where provided, telecommunication
devices shall be equipped with volume controls complying with ADAAG 4.31.5. In
the final rule, this requirement has been editorially revised and has been
clarified as applying to the telecommunication devices provided on the public
side of counters or teller windows.
Comment. Several commenters supported this section, while several
other commenters recommended modifications. For example, one commenter
recommended that knee and toe clearances be specified beneath counters. Another
commenter recommended that information display screens at counters should be
mounted at 43 to 51 inches from the floor.
Response. Since the counters addressed by this section are typically
used for brief periods of time in the conduct of business transactions, knee and
toe clearance underneath counters is not required as it is for fixed seating and
tables covered by ADAAG 4.32. Requirements for the mounting heights for
equipment have not been included in the absence of supporting technical
data.
10. Transportation Facilities
10.4 Airports
10.4.1 New Construction
10.4.1(8) Security Systems
This provision requires an accessible route complying with ADAAG 4.3 to be
provided at each single security barrier or group of security barriers in
airports covered by title II of the ADA as public facilities.
Comment. One commenter was concerned that the exemption for doors,
doorways and gates to be operated only by security personnel would limit job
opportunities for persons with disabilities.
Response. This provision applies to security gates at airport security
checkpoints. Such gates are designed to prevent air carrier passengers from
entering secured areas until they have been cleared. Normally, such gates are
adjacent to unobstructed routes allowing exiting passengers to leave the secured
area. Airport employees are typically allowed free access through such routes
and, therefore, employees with disabilities would not need to use the security
gate. A reference in this exception to ADAAG 4.13.6, which specifies maneuvering
clearances at doors, including latch-side clearance, has been removed. This
reference had been included in the interim rule for doors operated by security
personnel since such operation precludes the need for clearance at the latch
side of doors. However, since ADAAG 4.13.6 also contains specifications for
maneuvering space, which is essential for passage through doors, including those
operated by security personnel, it has been applied to these doors and gates. A
reference to "path of travel" in this exception has been changed to "circulation
path" to avoid confusion with the use of the term "path of travel" as it relates
to alterations to primary function areas in ADAAG 4.1.6(2).
11. Judicial, Legislative and Regulatory Facilities
This section addresses those facilities where judicial, legislative, and
regulatory functions occur. Judicial facilities consist of courthouses.
Legislative facilities include town halls, city council chambers, city or county
commissioners' meeting rooms, and State capitols. Regulatory facilities are
those which house State and local entities whose functions include regulating,
governing, or licensing activities. For example, this section would address
those rooms where school Board meetings, housing authority meetings, zoning
appeals, and adjudicatory hearings (e.g., drivers license suspensions) are
held.
Comment. Two commenters requested clarification of section 11 as it
applies to legislative and regulatory facilities. The commenters felt that
section 11 is so courtroom specific that it was difficult to extrapolate the
applicable requirements of seating for legislators, Board, council and
commission members.
Response. Section 11 has been reorganized to clarify the application
of requirements to judicial facilities (11.2) and to legislative and regulatory
facilities (11.3). Provisions applicable to all facilities covered by section 11
have been relocated to 11.1. An appendix note to 11.3 provides examples of
legislative and regulatory facilities to further clarify the application of this
section.
11.1 General
11.1.1 Entrances
This provision requires that, where provided, at least one restricted and at
least one secured entrance be accessible. Restricted entrances differ from
public entrances in that they are used only by judges, public officials,
facility personnel and other authorized parties, such as jurors on a controlled
basis. Secured entrances are used only by detainees and detention officers. The
interim rule exempted secured entrances operated only by security personnel from
ADAAG 4.13.6. However, since ADAAG 4.13.6 also contains specifications for
maneuvering space, which is essential for passage through doors, including those
operated by security personnel, the exemption from 4.13.6 has been removed. The
requirements in ADAAG 4.13 are not known to pose any conflict with security
requirements for doors. References in the interim rule to accessible routes have
been removed as section 4 of ADAAG requires that accessible entrances be
connected to an accessible route. Similarly, a requirement in the interim rule
for passenger loading zones provided for detainees has been removed as
accessible passenger loading zones are addressed in 4.1.2(5).
11.1.2 Security Systems
This provision requires an accessible route complying with ADAAG 4.3
(Accessible Route) to be provided through fixed security barriers at required
accessible entrances. Where security barriers incorporate equipment such as
metal detectors, fluoroscopes, or other similar devices which cannot be made
accessible, an accessible route is required adjacent to such security screening
devices to facilitate an equivalent circulation path. This provision has been
editorially revised to reference a circulation path in lieu of a path of travel.
No substantive changes have been made to this provision.
11.1.3 Two-way Communication Systems
This provision requires that where a two-way communication system is provided
to gain admittance to a facility or to restricted areas within the facility, the
system shall provide both visual and audible signals and shall comply with 4.27
(Controls and Operating Mechanisms). No changes have been made to this
provision.
11.2 Judicial Facilities
11.2.1 Courtrooms
ADAAG 11.2.1 applies to courtrooms in judicial facilities and requires access
to spectator seating and press areas, jury boxes, witness stands, judges'
benches, and other courtroom stations. Areas that are raised, such as witness
stands, or depressed and accessed by ramps or platform lifts with entry ramps
must provide a turning space complying with 4.2.3 so that the space can be
entered and exited in a forward direction safely. A reference to "depressed
areas" has been added to raised spaces and elements consistent with the
provision allowing use of platform lifts in 4.1.3(5), Exception 4. Requirements
in the interim rule for accessible routes, doors and gates, clear floor space,
and controls and operating mechanisms have been removed from the final rule as
they are addressed in ADAAG section 4.
Comment. Several commenters stated that a turning space is not
necessarily required within witness stands accessed by platform lifts.
Commenters provided examples of customized designs that incorporate lifts which
serve as the floor of the witness stand. This should obviate the necessity for
an entry ramp into the lift since the surface of the lift is level with the
adjacent floor.
Response. The requirement for unobstructed turning space has been
revised to apply only to raised or depressed areas accessed by ramps or platform
lifts with entry ramps. Enclosures and gates cannot restrict required
maneuvering spaces.
Comment. One commenter questioned whether doors to jury boxes must be
automatically operable.
Response. Where provided, doors and gates must comply with ADAAG 4.13
(Doors) which does not require automated doors, but does contain other technical
requirements.
Comment. In the interim rule, sections 11.2.1(2) (Jury Boxes and
Witness Stands), 11.2.1(4) (Fixed Judges' Benches, and Clerks' Stations),
11.2.1(5) (Fixed Bailiffs' Stations, Court Reporters' Stations, Litigants' and
Counsel Stations), and 11.2.1(6) (Fixed Lecterns) required that the maximum
height of controls and operating mechanisms be 48 inches. One commenter
questioned why control and operating mechanisms were restricted to a maximum
height of 48 inches when ADAAG allows up to 54 inches where a side approach is
provided.
Response. The interim rule provided that the maximum height for
controls and operating mechanisms was 48 inches. This limitation has been
removed in the final rule to allow a 54 inch side reach.
Comment. The interim final rule contained a requirement for access to
fixed lecterns which required knee space at least 27 inches high, 30 inches
wide, and 19 inches deep. Several commenters considered this requirement
excessive in view of standard lectern dimensions. Information was received
indicating that lecterns are typically not fixed in judicial facilities.
Response. This requirement has been removed in the final rule.
11.2.1(1)(a) Spectator, Press and Other Areas with Fixed Seats
This provision specifies the number of wheelchair spaces required where
spectator, press, or other areas with fixed seats are provided according to
ADAAG 4.1.3(19)(a). This requirement has been clarified in the final rule as
applying to each type of area with fixed seats.
Comment. The interim rule required that where spectator seating
capacity exceeds 50 and is located on one level that is not sloped or tiered,
accessible spaces must be provided in more than one seating row. One commenter
considered this requirement excessive and inconsistent with current ADAAG
requirements in 4.1.3(19)(a).
Response. This requirement has been removed in the final rule.
11.2.1(1)(b) Jury Boxes and Witness Stands
This provision requires at least one accessible wheelchair space within jury
boxes and witness stands. An exception allows that, in alterations, a wheelchair
space may be located outside the jury boxes or witness stands where providing
ramp or lift access poses a hazard by restricting or projecting into a means of
egress required by the appropriate local authority. A requirement in the interim
rule requiring counters in witness stands to comply with ADAAG 4.32 has been
removed since this provision which may be excessive for counters provided in
witness stands.
Comment. The interim rule recognized the use of portable lifts in
alterations where provision of a permanent platform lift is technically
infeasible. One commenter requested clarification regarding securement of
portable lifts. Concern was raised that portable lifts are subject to tipping if
they are not secured to the floor. Concern was also expressed over a potential
hazard where a ramp or platform lift would project into the circulation paths in
the well of a courtroom.
Response. The reference to portable lifts has been removed in the
final rule as it is not clear that all portable lifts meet the safety standard
referenced in ADAAG 4.11.2. This modification does not preclude the use of
portable platform lifts provided they fully comply with ADAAG 4.11.2. In
addition, the exception to this provision has been modified to allow placement
of a wheelchair accessible space outside raised witness stands and jury boxes in
alterations where a ramp or platform lift poses a hazard by restricting or
projecting into necessary circulation paths. The reference to technical
infeasibility has been removed as that exception is already provided in ADAAG
4.1.6(j).
11.2.1(1)(c) Judges' Benches and Courtroom Stations
This provision requires that judges' benches, clerks' stations, bailiffs'
stations, deputy clerks' stations, court reporters' stations, and litigants' and
counsel stations comply with ADAAG 4.32 (Fixed or Built-in Seating and Tables).
An exception permits designs that allow later installation of a means of
vertical access without substantial reconstruction of the space. This exception
has been clarified in the final rule.
Comment. A few commenters recommended that only a percentage of raised
judges' benches and clerks' stations be adaptable or accessible.
Response. Due to the complexity of courtroom design and the difficulty
of accommodating subsequent alterations, the Access Board believes that
requiring either accessible or adaptable judges' benches and clerks' stations
will significantly facilitate a reasonable accommodation for an employee in the
future.
11.2.1(2) Assistive Listening Systems
This section requires each courtroom in a judicial facility to have a
permanently installed assistive listening system complying with 4.33. This
provision specifies the minimum number of receivers for assistive listening
systems. This number must be equal or greater than four percent of the room
occupant load, but in no case less than two. This requirement is consistent with
ADAAG requirements for assembly areas in 4.1.3(19).
Comment. The interim rule provided that a permanently installed
assistive listening system was required in only 50 percent of certain areas in
judicial, legislative and regulatory facilities. Several commenters recommended
a requirement for 100 percent permanently installed assistive listening systems
in State and local government facilities. These commenters cited operational
problems such as scheduling and the inability of staff to locate and set up
portable systems. Other commenters preferred portable systems because they
believe them to be more flexible, cost effective and easier to replace as
technology evolves. Two commenters requested that smaller hearing rooms be
allowed to provide portable systems. The commenters stated that the majority of
hearing rooms are not utilized exclusively for adjudicatory proceedings but for
other purposes a disproportionate percentage of the time.
Response. The Access Board has revised the final rule to require a
permanently installed assistive listening system in each courtroom. A
requirement in the interim rule requiring permanently installed assistive
listening systems in 50 percent of hearing rooms, jury deliberation rooms, and
jury orientation rooms has been removed as these areas are addressed in ADAAG
4.1.3(19)(b). The definition of "assembly area" in ADAAG 3.5 has been clarified
as applying to those rooms or spaces accommodating a group of individuals for
"civic" purposes.
Comment. Information was submitted which addressed the incompatibility
of some receivers with hearing aids. People who wear hearing aids often need
them while using an assistive listening system. Ear buds require removal of
hearing aids. Headsets that cover the ear can produce disruptive interference
due to hearing aid T-coils. It was recommended that neckloops and headsets that
can be worn as neckloops be specified over other receiver types since they are
compatible with hearing aids.
Response. The compatibility of hearing aids and assistive listening
receivers is an issue that pertains not only to facilities covered in section 11
but to other assembly areas as well. The Access Board intends to consider this
issue in future rulemaking which would address assembly areas in general. An
appendix note has been added to the final rule recommending receivers that are
compatible with hearing aids.
Section 11.8 of the interim rule required electrical outlets and appropriate
wiring, conduit, or raceways in various areas, including courtrooms, to support
communication equipment for persons with disabilities. This requirement has been
removed as it may be too vague for purposes of design without further
specification on the type of equipment to be supported. Such equipment often is
portable and not appropriately addressed by ADAAG.
11.2.2 Jury Assembly Areas and Jury Deliberation Areas
This provision requires that where provided, refreshment areas and drinking
fountains in jury assembly areas and jury deliberation rooms must be accessible.
References in the interim rule to fixed seating and tables and vending machines
have been removed as ADAAG sections 4.1.3(18) and 5.8 address access to these
elements. In addition, the requirement for access to drinking fountains for
people who may have difficulty bending or stooping has been removed. The final
rule requires that where drinking fountains are provided, at least one comply
with ADAAG 4.15.
11.2.3 Courthouse Holding Facilities
Section 11.2.3(1) applies a scoping requirement to courthouse holding
facilities including central holding cells and court-floor holding cells serving
courtrooms. Where provided, at least one adult male, juvenile male, adult
female, and juvenile female central holding cell must comply with the
requirements in this section. Central holding facilities are typically designed
with sight and sound separation between men, women and juveniles. Where such
cell separation is provided, the guidelines require at least one of each type of
cell to be accessible. While there may be additional "types" of cells (i.e.,
isolation, group or individual cells) the definition of "type" is limited to
adult male, juvenile male, adult female, and juvenile female holding facilities.
Court-floor holding cells, however, are not necessarily designed with sight and
sound separation between adult males, juvenile males, adult females, and
juvenile females. For example, some courthouses have numerous courtrooms with
two court-floor holding cells provided between every two courtrooms. Detainees
are escorted through a secured route directly from the central holding cell to
the court-floor holding cell. In such instances, this provision would require
only one accessible court-floor holding cell. Such a cell may serve more than
one courtroom. A clarification has been added that cells may serve more than one
courtroom. No other changes have been made to this provision.
Section 11.2.3(2) contains the minimum requirements for accessible cells. In
the interim rule, 11.2.3(2)(a) (Doors and Doorways) exempted doors and doorways
operated only by security personnel from ADAAG 4.13.6. However, since ADAAG
4.13.6 also contains specifications for maneuvering space, which is essential
for passage through doors, including those operated by security personnel, the
exemption from 4.13.6 has been removed. The requirements in ADAAG 4.13 are not
known to pose any conflict with security requirements for doors. This provision
has also been modified to require fixed benches to provide back support (e.g.,
attachment to the wall).
Comment. One commenter requested that the term "maximum extent
feasible" be applied to situations where altering the facility would require
substantial demolition of the existing components of the facility in order to
come into compliance.
Response. If compliance with alterations requirements is technically
infeasible, ADAAG 4.1.6(1)(j) requires that the alteration provide accessibility
to the maximum extent feasible. Technically infeasible means, with respect to an
alteration of a building or a facility, that it has little likelihood of being
accomplished because existing structural conditions would require removing or
altering a load-bearing member which is an essential part of the structural
frame; or because other existing physical or site constraints prohibit
modification or addition of elements, spaces, or features which are in full and
strict compliance with the minimum requirements for new construction and which
are necessary to provide accessibility. Any elements or features of the building
or facility that are being altered and can be made accessible are required to be
made accessible within the scope of the alteration.
Comment. Several combination stainless steel water closet and lavatory
units are available that cannot incorporate a 36 inch grab bar behind the water
closet. One manufacturer of combination fixtures stated that the two main
reasons such units are specified is to reduce costs and minimize vandalism.
Combination units reduce the square footage needed in cell design and reduce
costs by only requiring one wall opening for plumbing connections, rather than
two wall openings if separate fixtures are provided. The commenter further
stated that there is a reduction in vandalism by having one large fixture
mounted to the wall which makes it much more difficult to remove or destroy than
a single lavatory or toilet. The commenter stated that major retooling and
redesign of the units would defeat the reasons why the units are currently
preferred and proposed that a 24 inch grab bar behind the water closet be
allowed instead of a 36 inch grab bar.
Response. Although the use of combination units are preferred for
space efficiency and security, they are generally not mandatory. An exception
for the length of the rear grab bar on combination units has not been provided
since separate, accessible lavatories and toilets are readily available.
Section 11.2.3(3) requires that where fixed cubicles are provided, at least
five percent, but not less than one, must have the maximum counter height and
knee clearance underneath as required by ADAAG 4.32 (Fixed or Built-in Seating
or Tables) on both the public and detainee sides. It also requires a method to
facilitate voice communication if solid partitions or security glazing separates
visitors from detainees. No changes have been made to this provision.
11.3 Legislative and Regulatory Facilities
This section contains requirements for legislative and regulatory facilities.
Legislative facilities include town halls, city council chambers, city or county
commissioners' meeting rooms, and State capitols. Regulatory facilities are
those which house State and local entities whose functions include regulating,
governing, or licensing activities. This section has been clarified in the final
rule as applying to public meeting rooms, hearing rooms, and chambers. An
appendix note provides examples of the facilities and spaces covered by this
section.
Section 11.3.1 requires access to raised speakers' platforms, spectator
seating and press areas. Areas that are raised such as speakers' platforms, or
depressed and accessed by ramps or platform lifts with entry ramps must provide
a turning space complying with 4.2.3 so that the space can be entered and exited
in a forward direction safely. For clarity, those requirements in the interim
rule applicable to hearing rooms and chambers are provided in this section
separately from those in 11.2 for courtrooms.
Section 11.3.1(1) requires access to at least one of each type of raised
speakers' platform. This provision has been revised for clarity and a reference
to ADAAG 4.32 has been removed since it may be excessive and not all speakers'
platforms contain counters. Section 11.3.1(2) addresses spectator, press, and
other areas. This provision has been revised consistent with a similar
requirement for courtrooms in 11.2. See 11.2.1(1)(a) above.
Most city council chambers and legislative chambers contain a public address
system and multiple microphones for numerous speakers. In such facilities, it is
more efficient to supplement an audio-amplification system with a permanently
installed assistive listening system to enable people who are deaf or hard of
hearing to participate in the proceedings. Section 11.3.2 requires a permanently
installed assistive listening system in each assembly area equipped with an
audio- amplification system. The interim rule required a permanently installed
assistive listening system in 50 percent of all hearing rooms, meeting rooms,
and chambers designated for public use. As revised in the final rule, this
provision is more consistent with existing ADAAG requirements in 4.1.3(19)(b).
This provision differs from 4.1.3(19)(b) in that it applies without respect to
occupancy load or the provision of fixed seating.
12. Detention and Correctional Facilities
This section addresses detention and correctional facilities where occupants
are under some degree of restraint or restriction for security reasons and
provides scoping and technical requirements for accessible cells or rooms.
12.1 General
This provision identifies the types of facilities covered by Section 12,
including jails, prisons, reformatories, and juvenile detention centers. All
public areas and those common use areas serving accessible cells are subject to
existing ADAAG except the requirements for areas of rescue assistance and
signage. In response to inquiries concerning the need for elevator access or
complying stairs to the upper tiers of housing facilities where there are no
accessible cells, an exception has been added in the final rule. Under this
exception, an elevator complying with 4.10 or stairs complying with 4.9 are not
required in multi-story housing facilities where accessible cells or rooms and
all common use areas serving them, as well as all public use areas, are on an
accessible route.
12.2 Entrances and Security Systems
This section covers entrances and security screening devices. Section 12.2.1
requires that public entrances, including those that are secured, be accessible
as required by ADAAG 4.1.3(8). Entrance doors that are operated by security
personnel are exempt from the requirements in ADAAG 4.13 (Doors) for door
hardware, opening forces, and automatic doors. Doors subject to security
requirements prohibiting full compliance with the provisions of ADAAG 4.13 are
similarly exempt. The exception in 12.2.1 may apply to doors used by persons
other than inmates and facility staff, such as counselors and instructors. It is
important that evacuation planning address egress for all persons who may access
secured areas since a person with a disability might not be able to
independently operate doors meeting this exception. This consideration has been
included in an appendix note. Section 12.2.2 requires that an accessible route
be provided through or around security screening devices located at accessible
entrances. Section 12.2.2 has been editorially revised to reference a
circulation path in lieu of a path of travel.
Section 12.2.2 of the interim rule contained requirements for entrances and
passenger loading zones used only by inmates or detainees and security
personnel. These requirement have been removed in the final rule as ADAAG
4.1.3(8) addresses all types of entrances except service entrances and ADAAG
4.1.2(5) addresses passenger loading zones.
Comment. In the interim rule, the exception in 12.2.1 for doors
subject to security requirements required compliance to the "maximum extent
feasible." One comment from a State agency recommended that this term be removed
because it complicates enforcement.
Response. The term "maximum extent feasible" has been removed from the
exception in 12.2.1 and the exception has been further modified for clarity. In
addition, a reference in this exception to ADAAG 4.13.6, which specifies
maneuvering clearances at doors, including latch- side clearance, has been
removed. This reference had been included in the interim rule for doors operated
by security personnel since such operation precludes the need for clearance at
the latch side of doors. However, since ADAAG 4.13.6 also contains
specifications for maneuvering space, which is essential for passage through
doors, including those operated by security personnel, the exemption from 4.13.6
has been removed. The requirements in ADAAG 4.13.6 are not known to pose any
conflict with security requirements for doors. An identical exception in
12.5.2(1) for doors and doorways serving holding or housing cells has been
similarly modified.
12.3 Visiting Areas
This section addresses non-contact visiting areas. At least five percent of
fixed cubicles on both the public and secured side must be accessible under
12.3(1). Accessible cubicles for inmates or detainees are required only in those
visiting areas serving accessible housing or holding cells. Section 12.3(2)
requires cubicles separated by solid partitions to be equipped with devices to
facilitate voice communication. These requirements are consistent with those for
visiting areas covered by section 11.4.3 (Courthouse Holding Facilities). Few
comments were received and only editorial changes have been made to this
provision.
12.4 Holding and Housing Cells or Rooms: Minimum Number
12.4.1 Holding Cells and General Housing Cells or Rooms
Minimum Number
This section requires that a minimum of two percent, but not less than one,
of the total number of holding or general housing cells or rooms provided in a
facility be accessible in new construction.
The interim rule provided that at least three percent, but not less than one,
of the total number of housing or holding cells or rooms provided in a facility
shall be accessible.
Comment. Most comments from detention and correctional authorities
considered the three percent minimum specified in the interim rule excessive in
view of the demonstrated need. Several State correctional agencies recommended
one percent. The Illinois Department of Corrections and 33 concurring State
correctional agencies urged that the minimum not exceed two percent. One
disability organization supported the three percent requirement. With respect to
detention facilities, one county government recommended one percent for holding
cells.
Most of the recommendations for a lower percentage were based on survey data
submitted in response to the NPRM. As noted in the interim rule, among various
responding States, the percentage of inmates with mobility impairments ranged
from .12 to 1.35 percent and the average was .46 percent. A survey conducted by
the Association of State Correctional Administrators (ASCA) provided a
significantly higher average of 3.39 percent, suggesting that a wider range of
disabilities, not just mobility impairments, was included. In response to the
interim rule, the California Department of Corrections compiled additional
survey data from States, the ASCA, and the Federal Bureau of Prisons. The
results of that survey indicated that the average percentage of inmates with
some type of disability is 1.56 percent.
Few comments provided survey data on city or county facilities. In response
to the NPRM, several State entities that oversee such facilities submitted
survey results. The percentage of inmates with disabilities housed in jails in
Nebraska and Texas was .07 percent and .48 percent, respectively. New York City
previously indicated that .25 percent of its inmate population used wheelchairs.
Other estimates for local facilities ranged from less than one percent to two
percent.
The three percent minimum specified in the interim rule was based in part on
the aging of the prison population, a consideration several commenters raised,
and existing data demonstrating that the prevalence of disability increases with
age. However, comments from State correctional agencies to the interim rule
indicated that the perceived aging of the prison population is not supported by
current demographic data. The California Department of Corrections indicated
that nationally the average age of inmates is 29.8 years and inmates aged 60
years or older comprise less than one percent of the total population based on
its survey of States. The Illinois Department of Corrections documented among
various States that the number of inmates over 50 years old has remained
constant or increased only slightly. The highest increase reported by any State
was 1.2 percent over a six year period. One comment from a county authority also
considered increases in this population to be negligible.
Response. Consistent with a large majority of commenters, as well as
the survey data provided, the minimum number of holding or general housing cells
or rooms required to be accessible in new construction has been reduced to two
percent.
Dispersion
The interim rule provided that accessible cells shall be dispersed among all
categories and types of general housing and holding areas. The final rule does
not contain a requirement for dispersion of accessible cells.
Comment. Many comments from State and local corrections officials
reiterated arguments made in response to the NPRM that accessible cells should
be required on a system-wide basis instead of for each newly built or altered
facility. This would provide a level of administrative discretion operators
consider essential in determining which facilities of a system are appropriate
for housing inmates with disabilities. According to the commenters, the
availability of certain programs, services, and staff, not just architectural
accessibility, are important criteria in making this determination and that
freedom of choice, a fundamental consideration in ensuring access to public
housing and transient lodging, is not pertinent to the assignment of housing
among inmates. The California Department of Corrections stated:
[T]he primary service of correctional facilities is to help maintain public
safety through incarceration of offenders. Classification to determine
placement within the system is based on many factors such as security
requirements, medical needs, and other administrative determinates.
Accessibility is another one of these factors in the classification process.
Given the mission of detention and correctional facilities, it is appropriate
to provide equal accessibility to programs, service, and activities in an
integrated environment in the most economic manner possible which includes
mitigating staffing costs, making use of community resources and grouping
inmates with disabilities to provide specialized services or training. The
Access Board's concept that assignment polices may change and that
construction opportunities applied piecemeal will eventually lead to full
accessibility is clearly based on assumptions of accessibility applied to most
government services and public accommodations. In a custodial setting,
accessibility is only one placement consideration which applies to an
extremely slight population number . . . . Accessibility can be optimally
provided in a limited number of facilities much more thoroughly and
economically, and with a comparable quality of providing inmate services,
programs, and activities.
Similar arguments were made by the Illinois Department of Corrections in
comments supported by 33 other State correctional entities. Commenters
emphasized these concerns in the context of alterations where requirements for
accessible cells may be triggered in existing facilities that cannot support
inmates with disabilities either architecturally or programmatically. According
to the commenters, provision of accessible cells in an alteration will by no
means ensure that the necessary level of access to programs, services, common
use areas and other amenities available to inmates will be achieved. According
to commenters, providing access in some existing facilities will waste limited
resources and lead to a greater number of accessible cells available only to
inmates without disabilities where misuse of elements, such as grab bars, is
more likely to occur. Thus, correctional authorities recommended that a
percentage of accessible cells be required for the entire system instead of at
each newly constructed or altered facility.
Response. New construction presents the greatest opportunity for
access. Why this would not hold true for detention and correctional facilities
was not clearly indicated in comments. Rather, the concerns expressed in this
area are relevant primarily to the requirement for access in alterations in
12.4.5 (Alterations to Cells or Rooms). In the interim rule, this provision
applied the minimum scoping percentage of new construction to the total number
of cells or rooms altered in a facility. Alterations provide important
opportunities for access as recognized by the ADA; however, corrections
authorities make a compelling case for allowing discretion in detention and
correctional facilities. Concerns of practicality, and those of feasibility
raised in the NPRM, and various operational factors indicate that in many
instances the cost of achieving access at many existing facilities will greatly
outweigh the benefits. For these reasons, section 12.4.5 and the requirement for
alterations have been reserved, thus limiting to new construction the two
percent scoping requirement. This requirement has been reserved, rather than
permanently removed, since it may be revisited in the future. Further, there
will be instances when the opportunities for access in alterations should be
considered, particularly where a system has few, if any, accessible cells. In
certain cases, complying with the requirements of section 12 may be practical,
technically feasible, and facilitate compliance with other ADA requirements,
including those for program access. While reserving this requirement may pose
confusion over the minimum level of access required in alterations, the
obligation correctional entities have in providing program access may
effectively and practically determine the degree of access that should be
provided in an alteration. The Department of Justice's title II regulation
states that public entities must operate each service, program, or activity so
that the service, program, or activity, when viewed in its entirety, is readily
accessible to and useable by individuals with disabilities. Thus, the lack of a
specific requirement for accessible prison alterations does not excuse a public
entity from providing access to all of the prison's programs and services, when
viewed in their entirety.
Comment. The interim rule contained a requirement that accessible
cells be dispersed among each type or category of housing or holding cells. A
few commenters recommended that prison operators have greater discretion in
locating cells on a site. The Bureau of Prisons noted that according to its
records inmates with disabilities are rarely housed in maximum security
facilities and recommended that accessible cells not be required in this
category of housing.
Response. The requirement for dispersion of accessible cells in each
category or type of housing or holding cell has been removed. Thus, at sites
where different categories of housing or levels of security are provided,
operators need not locate accessible cells in each category or security level. A
recommendation that accessible cells be dispersed among different types of
holding cells and different categories and security levels of housing has been
added to an appendix note.
Comment. Several commenters requested clarification that the minimum
percentage applies to a facility generally and that accessible cells are not
required in each building of a facility.
Response. The minimum scoping requirement of two percent is based on
the total number of housing or holding cells or rooms provided in a "facility."
As defined in ADAAG 3.5 (Definitions), the term "facility" includes the
buildings and structures of a site. While the percentage is based on the total
number of cells or rooms that may be provided at a site, the location of
accessible cells or rooms in each building is not required.
12.4.2 Special Holding and Housing Cells or Rooms
This section requires that where holding or housing cells or rooms are
provided for special purposes, at least one of each type must be accessible.
This includes those used for purposes of protective custody, disciplinary
detention, detoxification, and medical isolation.
Comment. One correctional authority recommended that this requirement
reference other purposes, including disciplinary segregation, administrative
detention, and orientation.
Response. These special purposes have been added to the
requirement.
Comment. The interim rule noted that "an accessible special holding or
housing cell or room may serve more than one purpose." One disability
organization indicated that this should only be permitted where inaccessible
cells also serve multiple purposes, otherwise inmates with disabilities may not
have access to the same level of service provided. This comment also suggested
that a recommendation be included in the appendix for a greater number of
accessible special purpose cells at large facilities.
Response. The statement concerning accessible cells serving more than
one purpose has been removed to ensure equivalency in the provision of access.
Accessible special holding cells may serve more than one purpose where other
special holding cells serve more than one purpose. Where special holding cells
serve different purposes, then one of each type must be accessible. This
clarification has been included as an appendix note to 12.4.2. Also added to
this appendix note is a recommendation that more than one of each type should be
accessible in large facilities where a number of cells of each type serve
different holding areas or housing units.
Comment. One correctional agency recommended that this section should
only apply to those medical isolation cells that are specifically designed for
that purpose and not general housing cells or medical care rooms that may also
be used to isolate inmates for medical purposes.
Response. An appendix note in the interim rule that distinguished
between medical isolation cells covered by 12.4.2 and patient bedrooms covered
by 12.4.4 has been relocated to this section. Additional clarification has been
added to this appendix note indicating that 12.4.2 applies to cells specifically
designed for purposes of medical isolation.
Comment. One corrections agency recommended that cells or rooms used
to monitor inmates or detainees likely to attempt suicide be exempt from the
requirement for grab bars. Such cells or rooms are typically designed without
any protrusions.
Response. The NPRM asked questions concerning grab bars and the risk
of suicide. A majority of the responses did not generally regard grab bars as
posing a greater risk since effective suicide prevention is based on a variety
of measures, including evaluation, classification, and surveillance of inmates,
not just cell design. However, the installation of grab bars may complicate the
design of facilities that are used for the purpose of suicide watch. An
exception to the requirement in ADAAG 4.16 (Water closets) for grab bars has
been added for cells or rooms specially designed to be used solely for the
purpose of suicide prevention.
12.4.3 Accessible Cells or Rooms for Persons with Hearing
Impairments
This section requires access for persons who are deaf or hard of hearing in
housing or holding cells or rooms equipped with audible emergency warning
systems or permanently installed telephones.
Comment. One State correctional authority recommended that the scoping
be reduced from three to one percent based on survey data received in response
to the NPRM.
Response. The data received in response to the NPRM indicated that the
population of inmates who are deaf or hard of hearing is only slightly higher
than the population of inmates with mobility impairments. Consistent with the
requirement for accessible cells in section 12.4.1, the minimum scoping has been
reduced from three to two percent.
12.4.4 Medical Care Facilities
This section applies the requirements of ADAAG 6 (Medical Care Facilities) to
medical care facilities in detention and correctional facilities. Few comments
addressed this provision and no changes have been made.
12.4.5 Alterations to Rooms or Cells
This section has been reserved. See the discussion under 12.4.1 (Holding
Cells and General Housing Cells or Rooms), "Dispersion".
12.5 Requirements for Accessible Cells or Rooms
This section contains the minimum requirements for accessible cells or rooms.
These requirements, which are similar to those for holding cells in judicial
facilities in ADAAG 11.4 (Courthouse Holding Facilities), are based primarily on
existing ADAAG specifications, including those for transient lodging in section
9 (Accessible Transient Lodging). Requirements are provided for doors and
doorways, toilet and bathing facilities, beds, drinking fountains, fixed seating
and tables, benches, storage, controls, and accommodations for persons with
hearing impairments. The majority of the comments received in response to this
provision addressed restrooms, beds, and fixed seating and tables.
Section 12.5.2 has been revised to address those situations where a covered
element or space serves an accessible cell or room but is located outside the
cell or room.
(1) Doors and Doorways
This section contains an exception for doors that are operated only by
security personnel or subject to security requirements prohibiting full
compliance from the requirements in ADAAG 4.13 (Doors). This exception has been
modified consistent with 12.2.1 and 12.2.2. (For further discussion of the
modifications, see 12.2 (Entrances).
(2) Toilet and Bathing Facilities
Comment. Several commenters recommended that a grab bar shorter than
the required 36 inches be permitted behind water closets so that combination
lavatory and water closet units may be used. Currently, such units are equipped
with a grab bar approximately 24 inches long. A manufacturer of such units
indicated that developing a fully compliant unit is cost-prohibitive.
Response. An exception for the length of the rear grab bar on
combination units has not been provided since separate, accessible lavatories
and toilets are readily available. For further discussion, see 11.4.2
(Requirements for Accessible Cells).
Comment. One commenter recommended that floor-mounted grab bars be
permitted.
Response. ADAAG does not specifically address floor-mounted grab bars.
However, in some situations they may provide an effective alternative to
wall-mounted grab bars so long as the requirements of ADAAG 4.26 (Handrails,
Grab Bars, and Tub and Shower Seats), including the specifications for
structural strength, are met.
(3) Beds
Comment. Several comments addressed the requirements for beds. One
comment recommended that the minimum clear floor space required along one side
of beds be 5 feet long instead of the full length of the bed. One comment from
an inmate with a disability recommended that headroom between bunkbeds be
specified while another commenter advised the height of beds should be 19 to 21
inches.
Response. Clear floor space 36 inches wide is required along side of
beds the full length. However, elements, such as writing counters, may overlap
this space so long as the required knee and toe clearance is provided. An
appendix note provides some guidance on headroom between bunkbeds and recommends
a height for beds of 17 to 19 inches based on existing ADAAG requirements for
water closets and benches. No changes have been made to this provision.
Technical inquiries have been received concerning the number of beds that
should be accessible in large barracks-style rooms with many beds. Since beds
may not be fixed, a minimum number of accessible beds is not specified in this
section, consistent with existing ADAAG. However, a recommendation has been
added to the appendix that the minimum scoping for cells or rooms (two percent)
also be applied to the number of beds in large cells or rooms with many
beds.
(4) Drinking Fountains
(5) Fixed or Built-In Seating and Tables
(6) Fixed Benches
One comment concerning fixed or built-in seating and tables seemed to confuse
the requirements of section 12.5.2 with those for common use areas in 12.1.
Section 12.5.2 applies only to elements located within accessible cells or
rooms. Those elements located outside cells for common use by inmates, such as
in dayrooms which adjoin cells, are subject to 12.1 and its application of
existing ADAAG for common use areas serving accessible cells. An appendix note
has been added to 12.5.2 to clarify this. In addition, the requirements in
12.5.2 for drinking fountains, fixed or built-in seating and tables, and fixed
benches have been modified to more clearly apply to elements located within
housing or holding cells. Paragraph (4) has been modified to require "at least
one" wheelchair accessible drinking fountain where provided within a holding or
housing cell. Drinking fountains located in common use areas are subject to
existing ADAAG and its requirement that drinking fountains be accessible to both
persons using wheelchairs and those who may have difficulty bending or stooping.
Paragraph (5), which covers fixed or built-in seating and tables, and paragraph
(6), which addresses fixed benches, has been similarly modified. In addition,
paragraph (6) has been modified to require fixed benches to be mounted to the
wall or provide back support.
(7) Storage
(8) Controls
(9) Accommodations for Persons with Hearing Impairments
Few comments addressed these sections and no changes have been made to these
provisions.
12.6 Visual Alarms and Telephones
This section contains technical requirements for cells that are accessible to
persons who are deaf or hard of hearing. Section 12.6 requires that where cells
are equipped with audible emergency warning systems, a visual alarm complying
with ADAAG 4.28.4 (Auxiliary Alarms) shall also be provided. This section also
requires that permanently installed telephones, if provided in cells, shall have
volume controls complying with ADAAG 4.31.5 (Hearing Aid Compatible and Volume
Control Telephones). An exception from the requirement for visual alarms is
provided where inmates or detainees are not allowed independent means of egress.
No substantive changes have been made to this provision.
The interim final rule clarified that portable devices may be used in lieu of
permanent devices if necessary wiring and outlets are provided. This was noted
as an example of "equivalent facilitation," a provision in ADAAG 2.2 that
permits alternative designs that provide equal or greater access. Since
equivalent facilitation pertains to all ADAAG provisions, this specific example
has been removed in the final rule.
Comment. The Committee on Acoustics in Corrections recommended that
design guidelines on acoustics developed by the American Correctional
Association should be incorporated in section 12. These specifications are
particularly essential in the noisy environments of detention and correctional
facilities and may help prevent hearing loss caused by constant exposure to loud
noise.
Response. Guidelines for acoustics have not been incorporated into
this rule because none had been previously recommended or proposed and made
available for public comment. While acoustics in correctional facilities is an
important design consideration, it involves concerns such as prevention of
hearing loss, that lie beyond the scope of ADAAG and its minimum criteria for
access to the built environment. Some of these issues may be more appropriately
addressed by agencies that oversee correctional systems or provide
accreditation.
13. Accessible Residential Housing
In the interim rule, ADAAG 13 addressed accessibility requirements for
residential facilities. This section has been reserved in the final rule.
Since the publication of the interim rule, the American National Standards
Institute (ANSI) A117 Committee has developed a draft proposal to add new
sections pertaining to accessible and adaptable residential housing to the
CABO/ANSI A117.1 standard. The CABO/ANSI standard for Accessible and Usable
Buildings and Facilities will be revised in 1997 to incorporate these new
technical and scoping provisions.
The Access Board is committed to coordinating its guidelines with private
sector standards and model codes to the extent possible. The development of
accessibility standards for accessible residential housing by the ANSI committee
at the time the Access Board is publishing guidelines in the same area, presents
a unique opportunity for the Access Board to promote greater uniformity in
accessibility standards. Accordingly, the Access Board is reserving ADAAG 13
(Accessible Residential Housing) until it has an opportunity to review the final
CABO/ANSI standard. Upon completion of its review, the Access Board will issue
guidelines for accessible residential housing.
14. Public Rights-of-Way
In the interim rule, ADAAG 14 included provisions for new construction and
alterations of pedestrian and related facilities in the public rights-of-way.
This section has been reserved in the final rule.
Comment. The majority of the comments received in response to the NPRM
and the interim rule concerned ADAAG 14 (Public Rights-of-Way). Commenters were
particularly concerned with the application of the new construction provisions
of section 14 to existing facilities. Many of these commenters, including public
works agencies, transportation departments, and traffic consultants, were
concerned that ADAAG 14.1 would be applied to transition plan construction, and
in particular, the number, location, and design of curb ramps, in existing
developed rights-of-way.
Response. Section 14 of the interim rule contained new construction
provisions which were not intended to apply to existing facilities in the public
right-of-way. With respect to alterations, section 14 contained less stringent
scoping and technical provisions for alterations to established rights-of-way
where there is site infeasibility. Few critical comments were directed to the
accessibility requirements for alterations. The response to both the NPRM and
the interim rule clearly indicated the need for substantial education and
outreach regarding the application of guidelines in this area.
Pedestrian facility design, and in particular, accessible pedestrian design,
is a new responsibility for many traffic engineers. Within the highway industry,
there is disparate understanding of pedestrian accessibility criteria generally,
and the application of the ADAAG 14 provisions for new construction contained in
the interim rule, in particular. As a result, the Access Board has elected to
reserve ADAAG 14 (Public Rights-of-Way) in this final rule. The Access Board has
embarked upon an ambitious program of outreach to governmental and private-
sector organizations in the transportation industry to promote the incorporation
of pedestrian accessibility criteria into current and proposed industry
guidelines, standards, and recommended practices. The guidelines contained in
section 14 of the interim rule have been adopted by the State of Alabama and are
being used to guide policies on pedestrian accessibility in the States of
California, New Jersey and Florida. Several cities, including Portland, Oregon
and Seattle, Washington have pedestrian planning requirements that are
substantially similar to those contained in the interim rule.
In a future rulemaking, the Access Board will review its education and
outreach program and the impact of the States' and localities' regulatory
efforts in this area, and will consider publication of requirements for
accessibility in the public right-of-way.
Technical Assistance
Under both the Architectural Barriers Act and the Americans with Disabilities
Act, the Access Board provides technical assistance and training for entities
covered under the acts. The Access Board's toll-free number allows callers to
receive technical assistance and to order publications. The Access Board
conducts in-depth training programs to advise and educate the general public, as
well as architects and other professionals on the accessibility guidelines and
requirements. In addition, the Access Board is developing a manual for use by
both technical and general audiences. The general manual on ADAAG requirements
will be a useful tool in understanding ADAAG whether for purposes of compliance
or as a reference for accessible design.
Regulatory Process Matters
Regulatory Assessment
These guidelines are issued to provide guidance to the Department of Justice
and the Department of Transportation in establishing accessibility standards for
new construction and alterations of State and local government facilities
covered by title II of the ADA. The standards established by the Department of
Justice and the Department of Transportation must be consistent with these
guidelines.
Under Executive Order 12866, the Board must determine whether these
guidelines are a significant regulatory action. The Executive Order defines a
"significant regulatory action" as one that is likely to result in a rule that
may:
"(1) Have an annual effect on the economy of $100 million or more or
adversely affect in a material way the economy, a sector of the economy,
productivity, competition, jobs, the environment, public health or safety, or
State, local, or tribal governments or communities;
(2) Create a serous inconsistency or otherwise interfere with an action
taken or planned by another agency;
(3) Materially alter the budgetary impact of entitlements, grants, user
fees, or loan programs or the rights and obligations of recipients thereof;
or
(4) Raise novel legal or policy issues arising out of legal mandates, the
President' priorities, or the principles set forth in the Executive
Order.
For significant regulatory actions that are expected to have an annual effect
on the economy of $100 million or more or adversely affect in a material way the
economy, a sector of the economy, productivity, competition, jobs, the
environment, public health or safety, or State, local or tribal governments or
communities, a written assessment must be prepared of the costs and benefits
anticipated from the regulatory action and any potentially effective and
reasonably feasible alternatives of the planned regulation. In both the proposed
and interim rules for accessibility guidelines for State and local government
buildings and facilities, the Board determined that those rules met the criteria
for a significant regulatory action in paragraph (1) above under Executive Order
12866. As a result, a Preliminary Regulatory Impact Analysis was prepared for
the proposed rule and a Regulatory Assessment was prepared for the interim final
rule. In addition to miscellaneous provisions, both the proposed rule and the
interim final rule addressed the addition of four new sections to the Americans
with Disabilities Accessibility Guidelines. Those sections included judicial,
legislative and regulatory facilities (section 11); detention and correctional
facilities (section 12); housing (section 13) and public rights-of-way (section
14).
As discussed in more detail in the Section-by-Section analysis above, there
have been three major revisions made in this final rule: (1) the reserving of
section 13 which previously addressed accessibility requirements in housing; (2)
the reserving of section 14 which addressed public rights-of-way; and (3) the
reduction of the scoping for accessible cells in detention facilities from three
percent to two percent. In addition, the final rule eliminates requirements for
(1) outlets, wiring and conduit for communications in judicial, regulatory and
legislative facilities; (2) areas of rescue assistance in detention facilities;
and reduces scoping requirements for visible alarms from three percent to two
percent in detention facilities. These and other revisions have greatly reduced
the economic impact previously imposed by the interim rule for State and local
government facilities. The final rule has created a small increase in costs in
only one aspect: in Section 11.2.2, the scoping for permanent listening systems
has been increased from 50 percent of the courtrooms to 100 percent of the
courtrooms. Accordingly, because the overall effect of the final rule reduces,
rather than increases, the impact of the interim final rule, the Board has
determined that this final rule does not meet the criteria for a significant
rule under paragraph (1) above in that it will not have an annual effect on the
economy of $100 million or more or adversely affect in a material way the
economy, a sector of the economy, productivity, competition, jobs, the
environment, public health or safety, or State, local, or tribal governments or
communities. Because the final rule does not meet the criteria under paragraph
(1) above, a regulatory assessment has not been prepared.
The Board and the Office of Management and Budget (OMB) have, however,
determined that this final rule meets the other criteria for a significant
regulatory action (i.e., the final rule raises novel, legal or policy issues
arising out of legal mandates), and OMB has reviewed the final rule.
The guidelines adhere to the principles of the Executive Order. Following the
issuance of the proposed rule, the Board held five public hearings in major
cities across the country. Notices of the hearings and invitations to attend
were sent to major state and local government entities in those areas. In
addition, copies of the notice of proposed rule and the interim final rule as
well as the regulatory assessments prepared in connection with those rules were
mailed directly to major associations of State and local governmental entities
across the country and various responsible agencies in individual states for
their review and comment. Those comments were carefully analyzed and the major
issues discussed in both the interim final rule and this final rule.
Regulatory Flexibility Act Analysis
Under the Regulatory Flexibility Act, the publication of a rule requires the
preparation of a regulatory flexibility analysis if such rule could have a
significant economic impact on a substantial number of small entities. For the
reasons discussed above, the Board has determined that these guidelines will not
have such an impact and accordingly, a regulatory flexibility act analysis has
not been prepared.
Federalism Statement
These guidelines will have limited Federalism impacts. The impacts imposed
upon State and local government entities are the necessary result of the ADA
itself. Every effort has been made by the Access Board to lessen the impact of
these guidelines on State and local government entities. As discussed in more
detail in the Section-by-Section analysis above, the final rule has revised the
ADA Accessibility Guidelines for State and Local Government facilities and has
greatly reduced the economic impact of the interim guidelines.
The Preliminary Regulatory Impact Analysis (PRIA) prepared in connection with
the proposed rulemaking and the Regulatory Assessment prepared for the interim
final rule served as the Federalism Statements for those rules under Executive
Order 12612. Because the overall impact of this final rule reduces rather than
increases the impact of the interim rule, an additional Federalism Statement is
unnecessary for purposes of this rule.
Unfunded Mandates Reform Act
Under the Unfunded Mandates Reform Act, Federal agencies must prepare a
written assessment of the effects of any Federal mandate in a final rule that
may result in the expenditure by State, local, and tribal governments, in the
aggregate, or by the private sector, of $100 million or more in any one year.
Excluded from the requirements of that Act, are provisions which (1) enforce the
constitutional rights of individuals; or (2) establish or enforce a statutory
right that prohibits discrimination on the basis of race, color, religion, sex,
national origin, age, handicap or disability. Guidelines promulgated pursuant to
the Americans with Disabilities Act are therefore excluded from the application
of the Unfunded Mandates Reform Act and a written assessment is not required for
this final rule.
Enhancing the Intergovernmental Partnership
As discussed in the supplementary information above, on December 21, 1992,
the Access Board published a NPRM in the Federal Register which proposed to
amend ADAAG (36 CFR part 1191) by adding four special application sections and
miscellaneous provisions specifically applicable to buildings and facilities
covered by title II of the ADA. Executive Order 12875, Enhancing the
Intergovernmental Partnership, encourages Federal agencies to consult with State
and local governments affected by the implementation of legislation.
Accordingly, following the issuance of the NPRM, the Access Board held five
public hearings in major cities across the country. Notices of the hearings and
invitations to attend were sent to major State and local government entities in
those areas. In addition, copies of the NPRM were mailed directly to major
associations of State and local governmental entities across the country and
various responsible agencies in individual States. In response to the NPRM and
the public hearings, a total of 148 people presented testimony on the proposed
guidelines, 447 written comments were submitted to the Access Board by the end
of the comment period, and an additional 127 comments were received after the
close of the comment period. Although the latter comments were not timely, the
Access Board considered them to the extent practicable. Two hundred and five of
the comments and testimony received were from affected State and local
governments.
In addition, following the publication in the Federal Register of the Access
Board's interim rule on June 20, 1994, and the notices of proposed rulemaking by
the departments of Justice and Transportation, copies of the Access Board's
interim rule and the departments' NPRMs, as well as the Regulatory Assessment
prepared in connection with the notices were forwarded to major State and local
government associations and agencies for their review and comment. The Access
Board received 246 comments on the interim rule. Almost two thirds of the
comments received were from State and local governments. Many of those comments
were from public works agencies, transportation departments, and traffic
consultants.
The comments received in response to the NPRMs issued by the Access Board,
the Department of Justice and the Department of Transportation, as well as the
Access Board's interim rule were carefully analyzed and the major issues are
discussed in the Section-by-Section Analysis, which also indicates the Access
Board's position on each issue.
List of Subjects in 36 CFR Part 1191
Buildings and facilities, Civil rights, Individuals with disabilities,
Transportation.
Authorized by vote of the Access Board on May 14, 1997.
_____________________________________________________
Patrick D. Cannon Chairperson, Architectural and Transportation Barriers
Compliance Board.
Endnotes
(1) On September 6, 1991, the Access Board amended ADAAG to include
additional requirements specifically applicable to transportation facilities
(section 10). See 56 FR 45500, 36 CFR 1191.1. On that same date, the Access
Board also published separate final guidelines to assist the Department of
Transportation in establishing accessibility standards for transportation
vehicles. See 56 FR 45530, 36 CFR part 1192. The Department of Transportation
has incorporated ADAAG and the Access Board's guidelines for transportation
vehicles and facilities in its final regulations. See 56 FR 45584 (September 6,
1991), 49 CFR parts 37 and 38.
(2) UFAS was developed by the General Services Administration, Department of
Defense, Department of Housing and Urban Development, and the United States
Postal Service to implement the Architectural Barriers Act of 1968 (42 U.S.C.
4151 et seq.) which requires certain federally financed buildings to be
accessible. Most Federal agencies reference UFAS as the accessibility standard
for buildings and facilities constructed or altered by recipients of Federal
financial assistance for purposes of section 504 of the Rehabilitation Act of
1973, as amended.
(3) In new construction and alterations, title III of the ADA does not
require elevators if a facility is less than three stories or has less than
3,000 square feet per story, unless the facility is a shopping center or mall; a
professional office of a health care provider; or a terminal, depot or other
station used for specified public transportation or an airport passenger
terminal. See 28 CFR 36.401(d) and 36.404.
These guidelines have not been incorporated in the Department of Justice
accessibility standards and are, therefore, not
enforceable.
For the reasons set forth in the preamble, Part 1191 of title 36 of the Code
of Federal Regulations is amended as follows:
PART 1191 - AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY GUIDELINES
FOR BUILDINGS AND FACILITIES
1. The authority citation for 36 CFR Part 1191 continues to read as
follows:
Authority: 42 U.S.C. 12204.
2. Appendix A to Part 1191 is amended by revising the title page, pages i,
ii, 1 through 14, 14A, 15, 54, 56, 59 through 63, 67, 71 through 76; and
removing pages 61A and 77 through 92 as set forth below.
3. In Part 1191, the appendix to appendix A is amended by revising pages A1,
A1A, A2, A15 through A21 and removing pages A22 through A30 as set forth
below.
The revisions read as follows:
* * *
* *
1. PURPOSE. This document contains
scoping and technical requirements for accessibility to buildings and facilities
by individuals with disabilities under the Americans with Disabilities Act (ADA)
of 1990. These scoping and technical requirements are to be applied during
the design, construction, and alteration of buildings and facilities covered by
titles II and III of the ADA to the extent required by regulations issued by
Federal agencies, including the Department of Justice and the Department of
Transportation, under the ADA.
The technical requirements in section 4
(Accessible Elements and Spaces: Scope and Technical Requirements), are the same
as those of the American National Standard Institute's document A117.1-1980,
except as noted in this text by italics. However, the requirements in sections
4.1.1 through 4.1.7 and the special application sections are different from ANSI
A117.1-1980 in their entirety and are printed in standard type.
The
illustrations and text of ANSI A117.1-1980 are reproduced with permission from
the American National Standards Institute. Copies of the standard may be
purchased from the American National Standards Institute at 1430 Broadway, New
York, New York 10018.
Paragraphs marked with an asterisk have related,
nonmandatory material in the Appendix. In the appendix, the corresponding
paragraph numbers are preceded by an A.
* * *
* *
3. MISCELLANEOUS INSTRUCTIONS AND DEFINITIONS.
* *
* * *
3.5 Definitions.
* *
* * *
- Alteration.
- An alteration is a change to a building or facility that affects or could
affect the usability of the building or facility or part thereof. Alterations
include, but are not limited to, remodeling, renovation, rehabilitation,
reconstruction, historic restoration, resurfacing of circulation paths or
vehicular ways, changes or rearrangement of the structural parts or elements,
and changes or rearrangement in the plan configuration of walls and
full-height partitions. Normal maintenance, reroofing, painting or
wallpapering, or changes to mechanical and electrical systems are not
alterations unless they affect the usability of the building or facility.
* * *
* *
- Assembly Area.
- A room or space accommodating a group of individuals for recreational,
educational, political, social, civic, or amusement purposes, or for the
consumption of food and drink.
* * *
* *
- Curb Ramp.
- A short ramp cutting through a curb or built up to it.
* * *
* *
- Private Facility.
- A place of public accommodation or a commercial facility subject to title
III of the ADA and 28 C.F.R. part 36 or a transportation facility subject to
title III of the ADA and 49 C.F.R. 37.45.
- Public Facility.
- A facility or portion of a facility constructed by, on behalf of, or for
the use of a public entity subject to title II of the ADA and 28 C.F.R. part
35 or to title II of the ADA and 49 C.F.R. 37.41 or 37.43.
* * *
* *
- TDD (Telecommunication Devices for the Deaf).
- See text
telephone.
- TTY (Tele-Typewriter).
- See text
telephone.
-
- * *
* * *
- Technically Infeasible.
- See 4.1.6(1)(j)
EXCEPTION.
-
- Text Telephone (TTY).
- Machinery or equipment that employs interactive text based communications
through the transmission of coded signals across the standard telephone
network. Text telephones can include, for example, devices known as TDDs
(telecommunication display devices or telecommunication devices for deaf
persons) or computers with special modems. Text telephones are also called
TTYs, an abbreviation for tele-typewriter.
* * *
* *
- Transient Lodging.*
- A building, facility, or portion thereof, excluding inpatient medical care
facilities and residential facilities, that contains sleeping accommodations.
Transient lodging may include, but is not limited to, resorts, group homes,
hotels, motels, and dormitories.
* * *
* *
4. ACCESSIBLE ELEMENTS AND SPACES: SCOPE AND
TECHNICAL REQUIREMENTS.
4.1 Minimum Requirements.
4.1.1*
Application.
(1) General. All areas of newly designed or newly
constructed buildings and facilities and altered portions of existing buildings
and facilities shall comply with section 4, unless otherwise provided in this
section or as modified in a special application section.
(2) Application Based on Building Use. Special
application sections provide additional requirements based on building use. When
a building or facility contains more than one use covered by a special
application section, each portion shall comply with the requirements for that
use.
* * *
* *
(5) General Exceptions.
* * *
* *
(b) Accessibility is not required to or in:
(i) raised areas used primarily for purposes of security or life or fire
safety, including, but not limited to, observation or lookout galleries,
prison guard towers, fire towers, or fixed life guard stands;
(ii) non-occupiable spaces accessed only by ladders, catwalks, crawl
spaces, very narrow passageways, tunnels, or freight (non-passenger)
elevators, and frequented only by service personnel for maintenance, repair,
or occasional monitoring of equipment; such spaces may include, but are not
limited to, elevator pits, elevator penthouses, piping or equipment
catwalks, water or sewage treatment pump rooms and stations, electric
substations and transformer vaults, and highway and tunnel utility
facilities; or
(iii) single occupant structures accessed only by a passageway that is
below grade or that is elevated above standard curb height, including, but
not limited to, toll booths accessed from underground
tunnels.
* * *
* *
4.1.3 Accessible Buildings: New Construction. Accessible buildings and
facilities shall meet the following minimum requirements:
* * *
* *
(5)* One passenger elevator complying with 4.10 shall
serve each level, including mezzanines, in all multi-story buildings and
facilities unless exempted below. If more than one elevator is provided, each
passenger elevator shall comply with 4.10.
EXCEPTION 1: Elevators are not required in:
(a) private facilities that are less than three stories or that have less
than 3000 square feet per story unless the building is a shopping center, a
shopping mall, or the professional office of a health care provider, or
another type of facility as determined by the Attorney General; or
(b) public facilities that are less than three stories and that are not
open to the general public if the story above or below the accessible ground
floor houses no more than five persons and is less than 500 square feet.
Examples may include, but are not limited to, drawbridge towers and boat
traffic towers, lock and dam control stations, and train dispatching
towers.
The elevator exemptions set forth in paragraphs (a) and (b) do not
obviate or limit in any way the obligation to comply with the other
accessibility requirements established in section 4.1.3. For
example, floors above or below the accessible ground floor must meet the
requirements of this section except for elevator service. If toilet or
bathing facilities are provided on a level not served by an elevator, then
toilet or bathing facilities must be provided on the accessible ground
floor. In new construction, if a building or facility is eligible for
exemption but a passenger elevator is nonetheless planned, that elevator
shall meet the requirements of 4.10 and
shall serve each level in the building. A passenger elevator that provides
service from a garage to only one level of a building or facility is not
required to serve other levels.
* * *
* *
EXCEPTION 4: Platform lifts (wheelchair lifts)
complying with 4.11 of this guideline and applicable State or local codes may
be used in lieu of an elevator only under the following conditions:
* * *
* *
(e) To provide access to raised judges' benches, clerks' stations,
speakers' platforms, jury boxes and witness stands or to depressed areas
such as the well of a court.
* * *
* *
EXCEPTION 5: Elevators located in air traffic control towers are not
required to serve the cab and the floor immediately below the
cab.
* * *
* *
(8) The requirements in (a) and (b) below shall be
satisfied independently:
(a)(i) At least 50 percent of all public entrances (excluding those in (b)
below) shall comply with 4.14. At least one must be a ground floor entrance.
Public entrances are any entrances that are not loading or service
entrances.
(ii) Accessible public entrances must be provided in a number at least
equivalent to the number of exits required by the applicable building or fire
codes. (This paragraph does not require an increase in the total number of
public entrances planned for a facility.)
(iii) An accessible public entrance must be provided to each tenancy in a
facility (for example, individual stores in a strip shopping center).
(iv) In detention and correctional facilities subject to section 12, public
entrances that are secured shall be accessible as required by 12.2.1.
One entrance may be considered as meeting more than one of the requirements
in (a). Where feasible, accessible public entrances shall be the entrances
used by the majority of people visiting or working in the building.
(b)(i) In addition, if direct access is provided for pedestrians from an
enclosed parking garage to the building, at least one direct entrance from the
garage to the building must be accessible.
(ii) If access is provided for pedestrians from a pedestrian tunnel or
elevated walkway, one entrance to the building from each tunnel or walkway
must be accessible.
(iii) In judicial, legislative, and regulatory facilities subject to
section 11, restricted and secured entrances shall be accessible in the number
required by 11.1.1.
One entrance may be considered as meeting more than one of the requirements
in (b).
Because entrances also serve as emergency exits whose proximity to all
parts of buildings and facilities is essential, it is preferable that all
entrances be accessible.
(c) If the only entrance to a building, or tenancy in a facility, is a
service entrance, that entrance shall be accessible.
(d) Entrances which are not accessible shall have directional signage
complying with 4.30.1, 4.30.2, 4.30.3, and 4.30.5, which indicates the
location of the nearest accessible entrance.
* * *
* *
(17) Public telephones.
* * *
* *
(c) The following shall be provided in accordance
with 4.31.9:
(i) If four or more public pay telephones (including both interior and
exterior telephones) are provided at a site of a private facility, and at
least one is in an interior location, then at least one interior public text
telephone (TTY) shall be provided. If an interior public pay telephone is
provided in a public use area in a building of a public facility, at least
one interior public text telephone (TTY) shall be provided in the building
in a public use area.
(ii) If an interior public pay telephone is provided in a private
facility that is a stadium or arena, a convention center, a hotel with a
convention center, or a covered mall, at least one interior public text
telephone (TTY) shall be provided in the facility. In stadiums, arenas and
convention centers which are public facilities, at least one public text
telephone (TTY) shall be provided on each floor level having at least one
interior public pay telephone.
(iii) If a public pay telephone is located in or adjacent to a hospital
emergency room, hospital recovery room, or hospital waiting room, one public
text telephone (TTY) shall be provided at each such location.
(iv) If an interior public pay telephone is provided in the secured area
of a detention or correctional facility subject to section 12, then at least
one public text telephone (TTY) shall also be provided in at least one
secured area. Secured areas are those areas used only by detainees or
inmates and security personnel.
- (d) Where a bank of telephones in the interior
of a building consists of three or more public pay telephones, at least one
public pay telephone in each such bank shall be equipped with a shelf and
outlet in compliance with 4.31.9(2).
-
- EXCEPTION: This requirement does not apply to the secured areas of
detention or correctional facilities where shelves and outlets are
prohibited for purposes of security or safety.
* * *
* *
4.1.5 Accessible Buildings: Additions. Each addition
to an existing building or facility shall be regarded as an alteration. Each
space or element added to the existing building or facility shall comply with
the applicable provisions of 4.1.1 to 4.1.3, Minimum Requirements (for New
Construction) and the applicable technical specifications of section 4 and the
special application sections. Each addition that affects or could affect the
usability of an area containing a primary function shall comply with 4.1.6(2).
4.1.6 Accessible Buildings: Alterations.
(1) General. Alterations to existing buildings and
facilities shall comply with the following:
* * *
* *
(k) EXCEPTION:
(i) These guidelines do not require the installation of an elevator in
an altered facility that is exempt from the requirement for an elevator
under 4.1.3(5).
(ii) The exemption provided in paragraph (i) does not obviate or limit
in any way the obligation to comply with the other accessibility
requirements established in these guidelines. For example, alterations to
floors above or below the ground floor must be accessible regardless of
whether the altered facility has an elevator. If a facility subject to the
elevator exemption set forth in paragraph (i) nonetheless has a passenger
elevator, that elevator shall meet, to the maximum extent feasible, the
accessibility requirements of these guidelines.
* * *
* *
4.1.7 Accessible Buildings: Historic Preservation.
(1)* Applicability:
- (a) General Rule. Alterations to a qualified historic building or
facility shall comply with 4.1.6 (Accessible Buildings:
Alterations), the applicable technical specifications of section 4 and the
applicable special application sections unless it is determined in
accordance with the procedures in 4.1.7(2) that compliance with the
requirements for accessible routes (exterior and interior), ramps,
entrances, or toilets would threaten or destroy the historic significance
of the building or facility in which case the alternative requirements in
4.1.7(3) may be used for the feature.
* * *
* *
4.30 Signage.
* * *
* *
4.30.7* Symbols of Accessibility.
* * *
* *
(3) Text Telephones (TTYs). Text telephones (TTYs)
required by 4.1.3(17)(c) shall be identified by the international TTY symbol
(Fig
43(c)). In addition, if a facility has a public text telephone (TTY),
directional signage indicating the location of the nearest text telephone
(TTY) shall be placed adjacent to all banks of telephones which do not contain
a text telephone (TTY). Such directional signage shall include the
international TTY symbol. If a facility has no banks of telephones, the
directional signage shall be provided at the entrance (e.g., in a building
directory).
* * *
* *
4.31 Telephones.
* * *
* *
4.31.9* Text Telephones (TTYs) Required by
4.1.
(1) Text telephones (TTYs) used with a pay telephone
shall be permanently affixed within, or adjacent to, the telephone enclosure.
If an acoustic coupler is used, the telephone cord shall be sufficiently long
to allow connection of the text telephone (TTY) and the telephone
receiver.
(2) Pay telephones designed to accommodate a portable
text telephone (TTY) shall be equipped with a shelf and an electrical outlet
within or adjacent to the telephone enclosure. The telephone handset shall be
capable of being placed flush on the surface of the shelf. The shelf shall be
capable of accommodating a text telephone (TTY) and shall have 6 in (152 mm)
minimum vertical clearance in the area where the text telephone (TTY) is to be
placed.
(3) Equivalent facilitation may be provided. For
example, a portable text telephone (TTY) may be made available in a hotel at
the registration desk if it is available on a 24-hour basis for use with
nearby public pay telephones. In this instance, at least one pay telephone
shall comply with paragraph 2 of this section. In addition, if an acoustic
coupler is used, the telephone handset cord shall be sufficiently long so as
to allow connection of the text telephone (TTY) and the telephone receiver.
Directional signage shall be provided and shall comply with
4.30.7
* * *
* *
5. RESTAURANTS AND
CAFETERIAS.
5.1* General. Except as specified or modified in this
section, restaurants and cafeterias shall comply with the requirements of
section 4. Where fixed tables (or dining counters where food is consumed but
there is no service) are provided, at least 5 percent, but not less than one, of
the fixed tables (or a portion of the dining counter) shall be accessible and
shall comply with 4.32 as required in 4.1.3(18). In establishments where
separate areas are designated for smoking and non-smoking patrons, the required
number of accessible fixed tables (or counters) shall be proportionally
distributed between the smoking and non-smoking areas. In new construction, and
where practicable in alterations, accessible fixed tables (or counters) shall be
distributed throughout the space or facility.
* * *
* *
6. MEDICAL CARE
FACILITIES.
6.1 General. Medical care facilities included
in this section are those in which people receive physical or medical treatment
or care and where persons may need assistance in responding to an emergency and
where the period of stay may exceed 24 hours. In addition to the requirements of
section 4, medical care facilities and buildings shall comply with 6.
* * *
* *
6.3 Patient Bedrooms. Provide accessible patient
bedrooms in compliance with section 4. Accessible patient bedrooms shall comply
with the following:
* * *
* *
7. BUSINESS, MERCANTILE AND
CIVIC.
7.1 General. In addition to the requirements of
section 4, the design of all areas used for business transactions with the
public shall comply with 7.
7.2 Sales and Service Counters, Teller Windows,
Information Counters.
(1) In areas used for transactions where counters have
cash registers and are provided for sales or distribution of goods or services
to the public, at least one of each type shall have a portion of the counter
which is at least 36 in (915mm) in length with a maximum height of 36 in (915
mm) above the finish floor. It shall be on an accessible route complying with
4.3. Such counters shall include, but are not limited to, counters in retail
stores, and distribution centers. The accessible counters must be dispersed
throughout the building or facility. In alterations where it is technically
infeasible to provide an accessible counter, an auxiliary counter meeting
these requirements may be provided.
(2) In areas used for transactions that may not have a
cash register but at which goods or services are sold or distributed
including, but not limited to, ticketing counters, teller stations,
registration counters in transient lodging facilities, information counters,
box office counters and library check-out areas, either:
(i) a portion of the main counter which is a minimum of 36 in (915 mm) in
length shall be provided with a maximum height of 36 in (915 mm); or
(ii) an auxiliary counter with a maximum height of 36 in (915 mm) in
close proximity to the main counter shall be provided; or
(iii) equivalent facilitation shall be provided (e.g., at a hotel
registration counter, equivalent facilitation might consist of: (1)
provision of a folding shelf attached to the main counter on which an
individual with a disability can write, and (2) use of the space on the side
of the counter or at the concierge desk, for handing materials back and
forth).
All accessible sales and service counters shall be on an accessible route
complying with 4.3.
(3)* In public facilities where counters or teller
windows have solid partitions or security glazing to separate personnel from
the public, at least one of each type shall provide a method to facilitate
voice communication. Such methods may include, but are not limited to,
grilles, slats, talk-through baffles, intercoms, or telephone handset devices.
The method of communication shall be accessible to both individuals who use
wheelchairs and individuals who have difficulty bending or stooping. If
provided for public use, at least one telephone communication device shall be
equipped with volume controls complying with 4.31.5. Hand-operable
communications devices, if provided, shall comply with 4.27.
(4)* Assistive Listening Systems. (Reserved).
* * *
* *
8. LIBRARIES.
8.1 General. In addition to the requirements of
section 4, the design of all public areas of a library shall comply with 8,
including reading and study areas, stacks, reference rooms, reserve areas, and
special facilities or collections.
* * *
* *
9. ACCESSIBLE TRANSIENT
LODGING.
(1) Except as specified in the special technical
provisions of this section, accessible transient lodging shall comply with the
applicable requirements of section 4. Transient lodging includes facilities or
portions thereof used for sleeping accommodations, when not classed as a
medical care facility.
* * *
* *
10. TRANSPORTATION
FACILITIES.
10.1 General. Every station, bus stop, bus stop pad,
terminal, building or other transportation facility, shall comply with the
applicable provisions of section 4, the special application sections, and the
applicable provisions of this section.
* * *
* *
10.4. Airports.
10.4.1 New Construction.
* * *
* *
- (8)* Security Systems. In public facilities that
are airports, at least one accessible route complying with 4.3 shall be
provided through fixed security barriers at each single barrier or group of
security barriers. A group is two or more security barriers immediately
adjacent to each other at a single location. Where security barriers
incorporate equipment such as metal detectors, fluoroscopes, or other
similar devices which cannot be made accessible, an accessible route shall
be provided adjacent to such security screening devices to facilitate an
equivalent circulation path. The circulation path shall permit persons with
disabilities passing through security barriers to maintain visual contact
with their personal items to the same extent provided other members of the
general public.
-
EXCEPTION: Doors, doorways, and gates designed to be operated only by
security personnel shall be exempt from 4.13.9, 4.13.11, and
4.13.12.
* * *
* *
11. JUDICIAL,
LEGISLATIVE AND REGULATORY FACILITIES.
11.1 General. In addition to the requirements in
section 4 and 11.1, judicial facilities shall comply with 11.2 and legislative
and regulatory facilities shall comply with 11.3.
- 11.1.1 Entrances. Where provided, at least one
restricted entrance and one secured entrance to the facility shall be
accessible in addition to the entrances required to be accessible by
4.1.3(8). Restricted entrances are those entrances used only by judges,
public officials, facility personnel or other authorized parties on a
controlled basis. Secured entrances are those entrances to judicial
facilities used only by detainees and detention officers.
-
- EXCEPTION: At secured entrances, doors and doorways operated only by
security personnel shall be exempt from 4.13.9, 4.13.10, 4.13.11 and
4.13.12.
11.1.2 Security Systems. An accessible route
complying with 4.3 shall be provided through fixed security barriers at
required accessible entrances. Where security barriers incorporate equipment
such as metal detectors, fluoroscopes, or other similar devices which cannot
be made accessible, an accessible route shall be provided adjacent to such
security screening devices to facilitate an equivalent circulation path.
11.1.3* Two-Way Communication Systems. Where a
two-way communication system is provided to gain admittance to a facility or
to restricted areas within the facility, the system shall provide both visual
and audible signals and shall comply with 4.27. Appendix
Note
11.2 Judicial Facilities.
11.2.1 Courtrooms.
- (1) Where provided, the following elements and
spaces shall be on an accessible route complying with 4.3. Areas that are
raised or depressed and accessed by ramps or platform lifts with entry ramps
shall provide unobstructed turning space complying with 4.2.3.
-
- EXCEPTION: Vertical access to raised judges' benches or courtroom
stations need not be installed provided that the requisite areas,
maneuvering spaces, and, if appropriate, electrical service are installed at
the time of initial construction to allow future installation of a means of
vertical access complying with 4.8, 4.10, or 4.11 without requiring
substantial reconstruction of the space.
(a) Spectator, Press, and Other Areas with Fixed
Seats. Where spectator, press or other areas with fixed seats are provided,
each type of seating area shall comply with 4.1.3(19)(a).
- (b) Jury Boxes and Witness Stands. Each jury
box and witness stand shall have within its defined area clear floor space
complying with 4.2.4.
-
- EXCEPTION: In alterations, accessible wheelchair spaces are not
required to be located within the defined area of raised jury boxes or
witness stands and may be located outside these spaces where ramp or lift
access poses a hazard by restricting or projecting into a means of egress
required by the appropriate administrative authority.
(c) Judges' Benches and Courtroom Stations.
Judges' benches, clerks' stations, bailiffs' stations, deputy clerks'
stations, court reporters' stations and litigants' and counsel stations
shall comply with 4.32.
(2)* Permanently installed assistive listening
systems complying with 4.33 shall be provided in each courtroom. The minimum
number of receivers shall be four percent of the room occupant load, as
determined by applicable State or local codes, but not less than two
receivers. An informational sign indicating the availability of an assistive
listening system and complying with 4.30.1, 4.30.2, 4.30.3, 4.30.5, and
4.30.7(4) shall be posted in a prominent place. Appendix
Note
11.2.2 Jury Assembly Areas and Jury Deliberation
Areas. Where provided in areas used for jury assembly or deliberation, the
following elements or spaces shall be on an accessible route complying with 4.3
and shall comply with the following provisions:
(1) Refreshment Areas. Refreshment areas,
kitchenettes and fixed or built-in refreshment dispensers shall comply with
the technical provisions of 9.2.2(7).
(2) Drinking Fountains. Where provided in rooms
covered under 11.2.2, there shall be a drinking fountain in each room
complying with 4.15.
11.2.3 Courthouse Holding Facilities.
(1) Holding Cells - Minimum Number. Where provided,
facilities for detainees, including central holding cells and court-floor
holding cells, shall comply with the following:
(a) Central Holding Cells. Where separate
central holding cells are provided for adult male, juvenile male, adult
female, or juvenile female, one of each type shall comply with 11.2.3(2).
Where central-holding cells are provided, which are not separated by age or
sex, at least one cell complying with 11.2.3(2) shall be provided.
(b) Court-Floor Holding Cells. Where separate
court-floor holding cells are provided for adult male, juvenile male, adult
female, or juvenile female, each courtroom shall be served by one cell of
each type complying with 11.2.3(2). Where court-floor holding cells are
provided, which are not separated by age or sex, courtrooms shall be served
by at least one cell complying with 11.2.3(2). Cells may serve more than one
courtroom.
(2) Requirements for Accessible Cells. Accessible
cells shall be on an accessible route complying with 4.3. Where provided, the
following elements or spaces serving accessible cells shall be accessible and
on an accessible route:
- (a) Doors and Doorways. All doors and
doorways to accessible spaces and on an accessible route shall comply with
4.13.
-
- EXCEPTION: Doors and doorways operated only by security personnel
shall be exempt from 4.13.9, 4.13.10, 4.13.11 and 4.13.12.
(b)* Toilet and Bathing Facilities. Toilet
facilities shall comply with 4.22 and bathing facilities shall comply with
4.23. Privacy screens shall not intrude on the clear floor space required
for fixtures or the accessible route. Appendix
Note
(c)* Beds. Beds shall have maneuvering space at
least 36 in (915 mm) wide along one side. Where more than one bed is
provided in a cell, the maneuvering space provided at adjacent beds may
overlap. Appendix
Note
(d) Drinking Fountains and Water Coolers.
Drinking fountains shall be accessible to individuals who use wheelchairs in
accordance with 4.15 and shall be accessible to those who have difficulty
bending or stooping. This can be accomplished by the use of a "hi-lo"
fountain; by providing one fountain accessible to those who use wheelchairs
and one fountain at a standard height convenient for those who have
difficulty bending; by providing a fountain accessible under 4.15 and a
water cooler; or by other such means as would achieve the required
accessibility for each group.
(e) Fixed or Built-in Seating and Tables. Fixed
or built-in seating, tables or counters shall comply with 4.32.
(f) Fixed Benches. Fixed benches shall be
mounted at 17 in to 19 in (430 mm to 485 mm) above the finish floor and
provide back support (e.g., attachment to wall). The structural strength of
the bench attachments shall comply with 4.26.3.
(3)* Visiting Areas. The following elements, where
provided, shall be located on an accessible route complying with 4.3 and shall
comply with the following provisions:
(a) Cubicles and Counters. Five percent, but not
less than one, of fixed cubicles shall comply with 4.32 on both the visitor
and detainee sides. Where counters are provided, a portion at least 36 in
(915 mm) in length shall comply with 4.32 on both the visitor and detainee
sides.
(b) Partitions. Solid partitions or security
glazing that separate visitors from detainees shall comply with
7.2(3). Appendix
Note
11.3* Legislative and Regulatory Facilities. Assembly
areas designated for public use, including public meeting rooms, hearing rooms,
and chambers shall comply with 11.3. Appendix
Note
11.3.1 Where provided, the following elements and
spaces shall be on an accessible route complying with 4.3. Areas that are raised
or depressed and accessed by ramps or platform lifts with entry ramps shall
provide unobstructed turning space complying with 4.2.3.
(1) Raised Speakers' Platforms. Where raised
speakers' platforms are provided, at least one of each type shall be
accessible.
(2) Spectator, Press, and Other Areas with Fixed
Seats. Where spectator, press or other areas with fixed seats are provided,
each type of seating area shall comply with 4.1.3(19)(a).
11.3.2* Each assembly area provided with a
permanently installed audio-amplification system shall have a permanently
installed assistive listening system. The minimum number of receivers shall be
four percent of the room occupant load, as determined by applicable State or
local codes, but not less than two receivers. An informational sign indicating
the availability of an assistive listening system and complying with 4.30.1,
4.30.2, 4.30.3, 4.30.5, and 4.30.7(4) shall be posted in a prominent
place. Appendix
Note
12. DETENTION AND CORRECTIONAL
FACILITIES.
12.1* General. This section applies to jails, holding
cells in police stations, prisons, juvenile detention centers, reformatories,
and other institutional occupancies where occupants are under some degree of
restraint or restriction for security reasons. Except as specified in this
section, detention and correctional facilities shall comply with the applicable
requirements of section 4. All common use areas serving accessible cells or
rooms and all public use areas are required to be designed and constructed to
comply with section 4. Appendix
Note
- EXCEPTIONS: Requirements for areas of rescue assistance in 4.1.3(9),
4.3.10, and 4.3.11 do not apply. Compliance with requirements for elevators in
4.1.3(5) and stairs 4.1.3(4) is not required in multi-story housing facilities
where accessible cells or rooms, all common use areas serving them, and all
public use areas are on an accessible route. Compliance with 4.1.3(16) is not
required in areas other than public use areas.
12.2 Entrances and Security Systems.
- 12.2.1* Entrances. Entrances used by the public,
including those that are secured, shall be accessible as required by
4.1.3(8). Appendix
Note
-
- EXCEPTION: Compliance with 4.13.9, 4.13.10, 4.13.11 and 4.13.12 is not
required at entrances, doors, or doorways that are operated only by security
personnel or where security requirements prohibit full compliance with these
provisions.
12.2.2 Security Systems. Where security systems are
provided at public or other entrances required to be accessible by 12.2.1 or
12.2.2, an accessible route complying with 4.3 shall be provided through fixed
security barriers. Where security barriers incorporate equipment such as metal
detectors, fluoroscopes, or other similar devices which cannot be made
accessible, an accessible route shall be provided adjacent to such security
screening devices to facilitate an equivalent circulation path.
12.3* Visiting Areas. In non-contact visiting areas
where inmates or detainees are separated from visitors, the following elements,
where provided, shall be accessible and located on an accessible route complying
with 4.3:
- (1) Cubicles and Counters. Five percent, but not
less than one, of fixed cubicles shall comply with 4.32 on both the visitor
and detainee or inmate sides. Where counters are provided, a portion at
least 36 in (915 mm) in length shall comply with 4.32 on both the visitor
and detainee or inmate sides.
-
- EXCEPTION: At non-contact visiting areas not serving accessible cells or
rooms, the requirements of 12.3(1) do not apply to the inmate or detainee
side of cubicles or counters.
(2) Partitions. Solid partitions or security glazing
separating visitors from inmates or detainees shall comply with 7.2(3).
Appendix
Note
12.4 Holding and Housing Cells or Rooms: Minimum
Number.
12.4.1* Holding Cells and General Housing Cells or
Rooms. At least two percent, but not less than one, of the total number of
housing or holding cells or rooms provided in a facility shall comply with
12.5. Appendix
Note
- 12.4.2* Special Holding and Housing Cells or
Rooms. In addition to the requirements of 12.4.1, where special holding or
housing cells or rooms are provided, at least one serving each purpose shall
comply with 12.5. An accessible special holding or housing cell or room may
serve more than one purpose. Cells or rooms subject to this requirement
include, but are not limited to, those used for purposes of orientation,
protective custody, administrative or disciplinary detention or segregation,
detoxification, and medical isolation. Appendix
Note
-
- EXCEPTION: Cells or rooms specially designed without protrusions and to be
used solely for purposes of suicide prevention are exempt from the requirement
for grab bars at water closets in 4.16.4.
12.4.3* Accessible Cells or Rooms for Persons with
Hearing Impairments. In addition to the requirements of 12.4.1, two percent,
but not less than one, of general housing or holding cells or rooms equipped
with audible emergency warning systems or permanently installed telephones
within the cell or room shall comply with the applicable requirements of
12.6. Appendix
Note
12.4.4 Medical Care Facilities. Medical care
facilities providing physical or medical treatment or care shall comply with the
applicable requirements of section 6.1, 6.3 and 6.4, if persons may need
assistance in emergencies and the period of stay may exceed 24 hours. Patient
bedrooms or cells required to be accessible under 6.1 and 6.3 shall be provided
in addition to any medical isolation cells required to be accessible under
12.4.2.
12.4.5 Alterations to Cells or Rooms. (Reserved.)
12.5 Requirements for Accessible Cells or Rooms.
12.5.1 General. Cells or rooms required to be
accessible by 12.4 shall comply with 12.5.
12.5.2* Minimum Requirements. Accessible cells or
rooms shall be on an accessible route complying with 4.3. Where provided to
serve accessible housing or holding cells or rooms, the following elements or
spaces shall be accessible and connected by an accessible route. Appendix
Note
- (1) Doors and Doorways. All doors and doorways on
an accessible route shall comply with 4.13.
-
- EXCEPTION: Compliance with 4.13.9, 4.13.10, 4.13.11 and 4.13.12 is not
required at entrances, doors, or doorways that are operated only by security
personnel or where security requirements prohibit full compliance with these
provisions.
(2)* Toilet and Bathing Facilities. At least one
toilet facility shall comply with 4.22 and one bathing facility shall comply
with 4.23. Privacy screens shall not intrude on the clear floor space required
for fixtures and the accessible route. Appendix
Note
(3)* Beds. Beds shall have maneuvering space at least
36 in (915 mm) wide along one side. Where more than one bed is provided in a
room or cell, the maneuvering space provided at adjacent beds may
overlap. Appendix
Note
(4) Drinking Fountains and Water Coolers. At least
one drinking fountain shall comply with 4.15.
(5) Fixed or Built-in Seating or Tables. Fixed or
built-in seating, tables and counters shall comply with 4.32.
(6) Fixed Benches. At least one fixed bench shall be
mounted at 17 in to 19 in (430 mm to 485 mm) above the finish floor and
provide back support (e.g., attachment to wall). The structural strength of
the bench attachments shall comply with 4.26.3.
(7) Storage. Fixed or built-in storage facilities,
such as cabinets, shelves, closets, and drawers, shall contain storage space
complying with 4.25.
(8) Controls. All controls intended for operation by
inmates shall comply with 4.27.
(9) Accommodations for persons with hearing
impairments required by 12.4.3 and complying with 12.6 shall be provided in
accessible cells or rooms.
12.6 Visual Alarms and Telephones.
- Where audible emergency warning systems are provided to serve the
occupants of holding or housing cells or rooms, visual alarms complying with
4.28.4 shall be provided. Where permanently installed telephones are provided
within holding or housing cells or rooms, they shall have volume controls
complying with 4.31.5.
-
- EXCEPTION: Visual alarms are not required where inmates or detainees are
not allowed independent means of egress.
-
13. RESIDENTIAL HOUSING [RESERVED]
14. PUBLIC RIGHTS-OF-WAY [RESERVED]
* * *
* *
APPENDIX:
* * *
* *
A3.0 Miscellaneous Instructions and Definitions.
A3.5 Definitions.
Transient Lodging. The Department of Justice's policy and rules
further define what is covered as transient lodging.
A4.0 Accessible Elements and Spaces: Scope and Technical
Requirements.
* * *
* *
A4.1.7 Accessible Buildings: Historic Preservation.
A4.1.7(1) The Department of Justice's
regulations implementing titles II and III of the ADA require alternative
methods of access where compliance with the special access provisions in
4.1.7(3) would threaten or destroy the historic significance of a qualified
historic facility. The requirement for public facilities subject to title II is
provided at 28 C.F.R. 35.154(b) and
the requirement for private facilities subject to title III is provided at 28 C.F.R. 36.405(b).
* * *
* *
A4.31.9(1) A public text telephone (TTY) may be
an integrated text telephone (TTY) pay telephone unit or a conventional portable
text telephone (TTY) that is permanently affixed within, or adjacent to, the
telephone enclosure. In order to be usable with a pay telephone, a text
telephone (TTY) which is not a single integrated text telephone (TTY) pay
telephone unit will require a shelf large enough (10 in (255 mm) wide by 10 in
(255 mm) deep with a 6 in (150 mm) vertical clearance minimum) to accommodate
the device, an electrical outlet, and a power cord.
A4.31.9(3) Movable or portable text telephones
(TTYs) may be used to provide equivalent facilitation. A text telephone (TTY)
should be readily available so that a person using it may access the text
telephone (TTY) easily and conveniently. As currently designed, pocket-type text
telephones (TTYs) for personal use do not accommodate a wide range of users.
Such devices would not be considered substantially equivalent to conventional
text telephones (TTYs). However, in the future as technology develops this could
change.
* * *
* *
A4.33.7 Types of Listening Systems. An assistive
listening system appropriate for an assembly area for a group of persons or
where the specific individuals are not known in advance, such as a playhouse,
lecture hall or movie theater, may be different from the system appropriate for
a particular individual provided as an auxiliary aid or as part of a reasonable
accommodation. The appropriate device for an individual is the type that
individual can use, whereas the appropriate system for an assembly area will
necessarily be geared toward the "average" or aggregate needs of various
individuals. A listening system that can be used from any seat in a seating area
is the most flexible way to meet this specification. Earphone jacks with
variable volume controls can benefit only people who have slight hearing loss
and do not help people who use hearing aids. At the present time, magnetic
induction loops are the most feasible type of listening system for people who
use hearing aids equipped with "T- coils," but people without hearing aids or
those with hearing aids not equipped with inductive pick-ups cannot use them
without special receivers. Radio frequency systems can be extremely effective
and inexpensive. People without hearing aids can use them, but people with
hearing aids need a special receiver to use them as they are presently designed.
If hearing aids had a jack to allow a by-pass of microphones, then radio
frequency systems would be suitable for people with and without hearing aids.
The Department of Justice's regulations implementing titles II and III of the
ADA require public accommodations to provide appropriate auxiliary aids and
services to ensure effective communication. See 28 C.F.R. 35.160, 28 C.F.R. 35.164, and 28 C.F.R. 36.303. Where assistive
listening systems are used to provide effective communication, the Department of
Justice considers it essential that a portion of receivers be compatible with
hearing aids.
Some listening systems may be subject to interference from other equipment
and feedback from hearing aids of people who are using the systems. Such
interference can be controlled by careful engineering design that anticipates
feedback sources in the surrounding area.
* * *
* *
A7.0 Business, Mercantile and Civic.
A7.2(3)(iii) Counter or Teller Windows with
Partitions. Methods of facilitating voice communication may include grilles,
slats, talk-through baffles, and other devices mounted directly into the
partition which users can speak directly into for effective communication. These
methods are required to be designed or placed so that they are accessible to a
person who is standing or seated. However, if the counter is only used by
persons in a seated position, then a method of facilitating communication which
is accessible to standing persons would not be necessary.
A7.2(4) Assistive Listening Systems. At all sales
and service counters, teller windows, box offices, and information kiosks where
a physical barrier separates service personnel and customers, it is recommended
that at least one permanently installed assistive listening device complying
with 4.33 be provided at each location or series. Where assistive listening
devices are installed, signage should be provided identifying those stations
which are so equipped.
* * *
* *
A10.0 Transportation Facilities.
A10.4 Airports.
A10.4.1(8) Security Systems. This provision
requires that, at a minimum, an accessible route or path of travel be provided
but does not require security equipment or screening devices to be accessible.
However, where barriers consist of movable equipment, it is recommended that
they comply with the provisions of this section to provide persons with
disabilities the ability to travel with the same ease and convenience as other
members of the general public.
* * *
* *
A11.0 Judicial, Legislative and Regulatory
Facilities.
A11.1.3 Two-Way Communication Systems. Two-way
communication entry systems must provide both voice and visual display so that
persons with hearing or speech impairments can utilize the system. This
requirement may be met with a device that would allow security personnel to
respond to a caller with a light indicating that assistance is on the way. It is
important that signage be provided to indicate the meaning of visual
signals.
A11.2.1(2) Assistive Listening Systems. People
who wear hearing aids often need them while using assistive listening systems.
The Department of Justice's regulation implementing title II of the ADA requires
public entities to provide appropriate auxiliary aids and services where
necessary to ensure effective communication. See 28 C.F.R. 35.160 and 28 C.F.R. 35.164. Where assistive
listening systems are used to provide effective communication, the Department of
Justice considers it essential that a portion of receivers be compatible with
hearing aids. Receivers that are not compatible include ear buds, which require
removal of hearing aids, and headsets that must be worn over the ear, which can
create disruptive interference in the transmission.
A11.2.3(2)(b) Toilet and Bathing Facilities.
The requirements of 4.22 for toilet rooms and 4.23 for bathrooms, bathing
facilities, and shower rooms do not preclude the placement of toilet or bathing
fixtures within housing or holding cells or rooms as long as the requirements
for toilet rooms and bathrooms, including maneuvering space, are met. In such
instances, the maneuvering space required within housing or holding cells or
rooms may also serve as the maneuvering space required in toilet rooms by 4.22
or in bathrooms or shower rooms by 4.23.
A11.2.3(2)(c) Beds. The height of beds
should be 17 in to 19 in (430 mm to 485 mm) measured from the finish floor to
the bed surface, including mattresses or bed rolls, to ensure appropriate
transfer from wheelchairs and other mobility aids. Where upper bunks are
provided, sufficient clearance should be provided between bunks so that the
transfer from wheelchairs to lower bunks is not restricted. Figure A3 provides
average human dimensions that should be considered in determining this
clearance.
A11.2.3(3) Visiting Areas. Accessible cubicles
or portions of counters may have fixed seats if the required clear floor space
is provided within the area defined by the cubicle. Consideration should be
given to the placement of grilles, talk-thru baffles, intercoms, telephone
handsets or other communication devices so they are usable from both the fixed
seat and from the accessible seating area. If an assistive listening system is
provided, the needs of the intended user and characteristics of the setting
should be considered as described in A4.33.7
and Table A2.
A11.3 Legislative and Regulatory Facilities.
Legislative facilities include town halls, city council chambers, city or county
commissioners' meeting rooms, and State capitols. Regulatory facilities are
those which house State and local entities whose functions include regulating,
governing, or licensing activities. Section 11.3 applies to rooms where public
debate, or discussion of local issues, laws, ordinances, or regulations take
place. Examples include, but are not limited to, legislative chambers and
hearing rooms, facilities where town, county council or school Board meetings,
and housing authority meetings are held, and rooms accommodating licensing or
other regulatory board hearings, adjudicatory administrative hearings (e.g.,
drivers license suspension hearings) and zoning application and waiver
proceedings.
A11.3.2 See A11.2.1(2).
A12.0 Detention and Correctional Facilities.
A12.1 General. All common use areas serving
accessible cells or rooms are required to be accessible. In detention and
correctional facilities, common use areas include those areas serving a group of
inmates or detainees, including, but not limited to, exercise yards and
recreation areas, workshops and areas of instruction or vocational training,
counseling centers, cafeterias, commissaries, medical facilities, and any other
rooms, spaces, or elements that are made available for the use of a group of
inmates or detainees. Detention and correctional facilities also contain areas
that may be regarded as common use areas which specifically serve a limited
number of housing cells or rooms. Where this occurs, only those common use areas
serving accessible cells or rooms would need to be accessible as required by
12.5. For example, several housing cells may be located at and served by a
dayroom or recreation room. In this instance, only those dayrooms serving
accessible housing cells or rooms would need to be accessible. However, common
use areas that do not serve accessible cells but that are used by the public or
by employees as work areas are still subject to the requirements for public use
areas and employee work areas in section 4.
A12.2.1 Entrances. Persons other than inmates and
facility staff, such as counselors and instructors, may have access to secured
areas. It is important that evacuation planning address egress for all possible
users since a person with a disability might not be able to independently
operate doors permitted by this exception.
A12.3 Visiting Areas. Accessible cubicles or
portions of counters may have fixed seats if the required clear floor space is
provided within the area defined by the cubicle. Consideration should be given
to the placement of grilles, talk-thru baffles, intercoms, telephone handsets or
other communication devices so they are usable from both the fixed seat and from
the accessible seating area. If an assistive listening system is provided, the
needs of the intended user and characteristics of the setting should be
considered as described in A4.33.7
and Table A2.
A12.4.1 Holding Cells and General Housing Cells or
Rooms. Accessible cells or rooms should be dispersed among different levels
of security, housing categories and holding classifications (e.g., male/female
and adult/juvenile) to facilitate access. Many detention and correctional
facilities are designed so that certain areas (e.g., "shift" areas) can be
adapted to serve as different types of housing according to need. For example, a
shift area serving as a medium security housing unit might be redesignated for a
period of time as a high security housing unit to meet capacity needs. Placement
of accessible cells or rooms in shift areas may allow additional flexibility in
meeting requirements for dispersion of accessible cells or rooms.
A12.4.2 Special Holding and Housing Cells or
Rooms. While one of each type of special purpose cell is required to be
accessible at a facility, constructing more than one of each type to be
accessible will facilitate access at large facilities where cells of each type
serve different holding areas or housing units. The requirement for medical
isolation cells applies only to those specifically designed for medical
isolation. Cells or rooms primarily designed for other purposes, such as general
housing or medical care, are subject to the requirements in 12.4.1 or 12.4.4,
respectively. Medical isolation cells required to be accessible by 12.4.2 shall
not be counted as part of the minimum number of patient bedrooms or cells
required to be accessible in 12.4.4. Thus, if a medical care facility has both
types of cells, at least one medical isolation cell must be accessible under
12.4.2 in addition to the number of patient bedrooms or cells required to be
accessible by 12.4.4. While only one medical isolation cell per facility is
required to be accessible, it is recommended that consideration be given to
ensuring the accessibility of all medical isolation cells.
A12.4.3 Accessible Cells or Rooms for Persons with
Hearing Impairments. Many correctional facilities do not provide permanently
installed telephones or alarms within individual housing cells. Such facilities
are not subject to the requirements of 12.4.3. However, some categories of
housing, such as minimum security prisons, may be equipped with such devices.
The minimum two percent is based on the number of cells or rooms equipped with
these devices and not on the total number of cells or rooms in the facility. In
addition, this requirement applies only where permanently installed telephones
or alarms are provided within individual cells. Permanently installed telephones
and alarms located in common use areas, such as dayrooms, are required to be
accessible according to the requirements for common use areas. See 12.1.
A12.5.2 Minimum Requirements. The requirements of
this section apply to elements provided within housing or holding cells or
rooms. Elements located outside cells or rooms for common use, such as in a day
room, are subject to 12.1 and its application of requirements in section 4. For
example, if a drinking fountain is provided within an accessible housing or
holding cell, at least one must be wheelchair accessible under section
12.5.2(4). Drinking fountains located outside the cells in common use areas
serving accessible cells or in public use areas, are subject to the requirements
of 4.1.3(10).
A12.5.2(2) Toilet and Bathing Facilities. The
requirements of 4.22 for toilet rooms and 4.23 for bathrooms, bathing
facilities, and shower rooms do not preclude the placement of toilet or bathing
fixtures within housing or holding cells or rooms as long as the requirements
for toilet rooms and bathrooms, including maneuvering space, are met. In such
instances, the maneuvering space required within housing or holding cells or
rooms may also serve as the maneuvering space required in toilet rooms by 4.22
or in bathrooms or shower rooms by 4.23.
A12.5.2(3) Beds. Since beds may not always be
fixed, a minimum number of accessible beds has not been specified. In
barracks-style rooms with many beds, it is recommended that the scoping
requirement for housing or holding cells or rooms (2 percent) also be applied to
the number of beds in accessible cells or rooms.
The height of beds should be 17 to 19 in (430 mm to 485 mm) measured from the
finish floor to the bed surface, including mattresses or bed rolls, to ensure
appropriate transfer from wheelchairs and other mobility aids. Where upper bunks
are provided, sufficient clearance must be provided between bunks so that the
transfer from wheelchairs to lower bunks is not restricted. Figure A3 provides
standard human dimensions that should be considered in determining this
clearance.
|